High Power GaAs SPDT Switch
DC - 2.0 GHz
Typical Performance Curves
Insertion Loss
1.0
0.8
0.6
+25°C
-40°C
+85°C
0.4
0.2
0.0
0.5
1.0
1.5
2.0
Frequency (GHz)
VSWR
2.0
1.8
+25°C
-40°C
+85°C
1.6
1.4
1.2
1.0
0.5
1.0
1.5
2.0
Frequency (GHz)
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
RoHS
Compliant
MASWSS0161
V3
Isolation
40
35
30
25
+25°C
-40°C
85°C
20
15
0.5
1.0
1.5
2.0
Frequency (GHz)
Compression vs. Control Voltage @ 900 MHz
40
1dB
.1dB
35
30
25
20
15
10
3
4
5
6
7
8
9
10
Control Voltage (VDC)
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.