¡ Semiconductor
MSM9836-xxx
4. Stop Code Input Timing
I6 to I0 (I)
ST ( I )
"0000000"
tSS
User phrase
NAR (O)
BUSY (O)
AOUT (O)
Voice stop
When I6-I0 are set to "0000000" during voice playback (during the output of "L" level at the BUSY
pin), and a ST signal is input, playback stops regardless of whether NAR is at "H" or "L" level and
AOUT becomes 1/2 IAOUT. Stop code becomes valid at the falling edge of ST.
The stop code does not initialize internal units but only stops playback. To initialize an internal
register, use the RESET pin.
10/23