MPIC2111
ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise specified)
Characteristic
Symbol
Min
Typ
Max
Unit
STATIC ELECTRICAL CHARACTERISTICS
VBIAS (VCC, VBS) = 15 V unless otherwise specified. The VIN, VTH and IIN parameters are referenced to COM. The VO and IO parameters
are referenced to COM and are applicable to the respective output leads: HO or LO.
Logic “1” Input Voltage for HO & Logic “0” Input Voltage for LO @ VCC = 10 V
VIH
6.4
Logic “1” Input Voltage for HO & Logic “0” Input Voltage for LO @ VCC = 15 V
VIH
9.5
Logic “1” Input Voltage for HO & Logic “0” Input Voltage for LO @ VCC = 20 V
VIH
12.6
Logic “0” Input Voltage for HO & Logic “1” Input Voltage for LO @ VCC = 10 V
VIL
–
Logic “0” Input Voltage for HO & Logic “1” Input Voltage for LO @ VCC = 15 V
VIL
–
Logic “0” Input Voltage for HO & Logic “1” Input Voltage for LO @ VCC = 20 V
VIL
–
High Level Output Voltage, VBIAS–VO @ IO = 0 A
VOH
–
Low Level Output Voltage, VO @ IO = 0 A
VOL
–
Offset Supply Leakage Current @ VB = VS = 600 V
ILK
–
Quiescent VBS Supply Current @ VIN = 0 V or VCC
IQBS
–
Quiescent VCC Supply Current @ VIN = 0 V or VCC
IQCC
–
Logic “1” Input Bias Current @ VIN = 15 V
IIN+
–
Logic “0” Input Bias Current @ VIN = 0 V
IIN–
–
VBS Supply Undervoltage Positive Going Threshold
VBSUV+
–
VBS Supply Undervoltage Negative Going Threshold
VBSUV–
–
VCC Supply Undervoltage Positive Going Threshold
VCCUV+
–
VCC Supply Undervoltage Negative Going Threshold
VCCUV–
–
Output High Short Circuit Pulsed Current @ VOUT = 0 V, PW ≤ 10 µs
IO+
200
Output Low Short Circuit Pulsed Current @ VOUT = 15 V, PW ≤ 10 µs
IO–
420
–
–
VDC
–
–
–
–
–
3.8
–
6.0
–
8.3
–
100
mV
–
100
–
50
µA
50
–
70
–
20
40
–
1.0
8.5
–
V
8.2
–
8.6
–
8.2
–
250
–
mA
500
–
DYNAMIC ELECTRICAL CHARACTERISTICS
VBIAS (VCC, VBS) = 15 V unless otherwise specified
Turn–On Propagation Delay @ VS = 0 V
Turn–Off Propagation Delay @ VS = 600 V
Turn–On Rise Time @ CL = 1000 pF
Turn–Off Fall Time @ CL = 1000 pF
Deadtime, LS Turn–Off to HS Turn–On & HS Turn–Off to LS Turn–On
ton
–
850
–
ns
toff
–
150
–
tr
–
80
–
tf
–
40
–
DT
–
700
–
Delay Matching, HS & LS Turn–On/Off
MT
–
30
–
TYPICAL CONNECTION
10 TO 600 V
VCC
VCC
VB
IN
IN
HO
COM
VS
LO
TO
LOAD