Trigger Timing
HT761X
Note: 1. The output is activated if the trigger signal conforms to the following criteria:
More then 3 triggers within 2 seconds.
A trigger signal sustain duration 0.34 secs.
2 trigger signals within 2 secs with one of the trigger signal sustain 0.16 secs.
2. The effective comparator output width can be selected to be 24ms or 32ms or
48ms by mask option. The default is 24ms (system frequency=16KHz).
3. The output duration is set by an external RC that is connected to the OSCD pin.