Preliminary Information
MH88631
Pin Description (Continued)
Pin # Name
Description
21
XB
External relay contact (K1) connection from XC (Pin 8), activated by loop seize control input
(RC1).
22
VEE Negative Power Supply. (-5V).
23
VDD Positive Power Supply. (+5V)
24 RXOUT Audio receive signal (output) tothe RXIN- (Pin 13), via an external decoupling capacitor
(C3).
25
VCC+ Positive analog Power Supply Voltage. (+12V).
26
GSR Gain Setting Receive (Input). Normally used to set the receive gain with an external
resistor connected to RXOUT (Pin 24).
27
TXIN- Transmit (Input). Differential audio signal from VTR- (Pin 6), via an external capacitor
(C4).
28
VCC- Negative Analog Power Supply Voltage. (-12V).
29
TXIN+ Transmit (Input). Differential audio signal from VTR- (Pin 6), via an external decoupling
capacitor (C1).
30
AGND Analog Ground.
31
VR
Audio Receive (Input). The four-wire audio signal input to the interface.
32
VX
Audio Transmit (Output). The four-wire audio signal output from the interface.
33
RGND Relay Ground.
34
GSX Gain Setting Transmit (Input). Normally used to set the transmit gain with an external
resistor connected to VX (Pin 32).
35
RC1 Relay Control 1 (Input). A logic high will activate the relay (K1) to provide loop seize
across Tip and Ring.
36 NETBAL Network Balance (Input). When there is no connection (open), the network is balanced at
600. When the pin is grounded, the network is balanced at AT&T compromise.
37
RD1 Relay Driver 1 (Output). Open collector sinks current when RC1 is high. Diode clamp
protected.
38
CD Clamping Diode. Normally connects to the positive supply voltage.
39
RD2 Relay Driver 2 (Output). Open collector sinks current when RC2 is high. Diode clamp
protected.
40
RC2 Relay Driver 2 (Input). A logic high will activate the relay (K2) to provide proper biasing to
the Tip and Ring. This input control is used for Ground Start Trunk only.