datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

74ACT86 Ver la hoja de datos (PDF) - STMicroelectronics

Número de pieza
componentes Descripción
Lista de partido
74ACT86
ST-Microelectronics
STMicroelectronics ST-Microelectronics
74ACT86 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
74ACT86
DC SPECIFICATIONS
Test Condition
Value
Symbol
Parameter
VCC
(V)
TA = 25°C
Min. Typ. Max.
VIH High Level Input
4.5
VO = 0.1 V or
2.0 1.5
Voltage
5.5
VCC-0.1V
2.0 1.5
VIL Low Level Input
Voltage
4.5
VO = 0.1 V or
5.5
VCC-0.1V
1.5 0.8
1.5 0.8
VOH High Level Output 4.5
Voltage
5.5
IO=-50 µA
IO=-50 µA
4.4 4.49
5.4 5.49
4.5
IO=-24 mA
3.86
5.5
IO=-24 mA
4.86
VOL Low Level Output 4.5
Voltage
5.5
IO=50 µA
IO=50 µA
0.001 0.1
0.001 0.1
4.5
IO=24 mA
0.36
5.5
IO=24 mA
0.36
II
Input Leakage Cur-
rent
5.5
VI = VCC or GND
± 0.1
ICCT Max ICC/Input
5.5 VI = VCC - 2.1V
0.6
ICC
Quiescent Supply
Current
5.5 VI = VCC or GND
2
IOLD
IOHD
Dynamic Output
Current (note 1, 2)
5.5 VOLD = 1.65 V max
VOHD = 3.85 V min
1) Maximum test duration 2ms, one output loaded at time
2) Incident wave switching is guaranteed on transmission lines with impedances as low as 50
-40 to 85°C -55 to 125°C
Min. Max. Min. Max.
2.0
2.0
2.0
2.0
0.8
0.8
0.8
0.8
4.4
4.4
5.4
5.4
3.76
3.7
4.76
4.7
0.1
0.1
0.1
0.1
0.44
0.5
0.44
0.5
±1
±1
1.5
1.6
20
40
75
50
-75
-50
Unit
V
V
V
µA
mA
µA
mA
mA
AC ELECTRICAL CHARACTERISTICS (CL = 50 pF, RL = 500 , Input tr = tf = 3ns)
Test Condition
Value
Symbol
Parameter
VCC
(V)
tPLH tPHL Propagation Delay
Time
5.0(*)
TA = 25°C
-40 to 85°C -55 to 125°C Unit
Min. Typ. Max. Min. Max. Min. Max.
1.5 5.0 9.5 1.0 10.5 1.0 10.5 ns
(*) Voltage range is 5.0V ± 0.5V
CAPACITIVE CHARACTERISTICS
Test Condition
Value
Symbol
Parameter
VCC
(V)
TA = 25°C
-40 to 85°C -55 to 125°C Unit
Min. Typ. Max. Min. Max. Min. Max.
CIN Input Capacitance 5.0
5
pF
CPD Power Dissipation
Capacitance (note 5.0
fIN = 10MHz
30
pF
1)
1) CPD is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current consumption without
load. (Refer to Test Circuit). Average operating current can be obtained by the following equation. ICC(opr) = CPD x VCC x fIN + ICC/4 (per gate)
3/8

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]