XR16C864
2.97V TO 5.5V QUAD UART WITH 128-BYTE FIFO
áç
REV. 2.0.1
Pin Description
NAME
100-QFP
TYPE
PIN #
DESCRIPTION
DTRA#
DTRB#
DTRC#
DTRD#
9
O UART channels A-D Data-Terminal-Ready (active low) or general purpose output. If
21
these outputs are not used, leave them unconnected.
60
72
DSRA#
7
I UART channels A-D Data-Set-Ready (active low) or general purpose input. This input
DSRB#
23
should be connected to VCC when not used.
DSRC#
58
DSRD#
74
CDA#
CDB#
CDC#
CDD#
99
I UART channels A-D Carrier-Detect (active low) or general purpose input. This input
32
should be connected to VCC when not used.
49
83
RIA#
RIB#
RIC#
RID#
98
I UART channels A-D Ring-Indicator (active low) or general purpose input. This input
33
should be connected to VCC when not used.
48
84
OP1A#
OP1B#
OP1C#
OP1D#
3
O General purpose output or RS-485 direction control signal. RS-485 direction control can
28
be selected via FCTR bit-3. See “Auto RS485 Half-duplex Control” on page 18. If these
53
outputs are unused, leave them unconnected.
78
OP2A#
OP2B#
OP2C#
OP2D#
2
O General purpose output. If these outputs are unused, leave them unconnected.
29
52
79
ANCILLARY SIGNALS
XTAL1
40
I Crystal or external clock input. This input is not 5V tolerant.
XTAL2
41
O Crystal or buffered clock output.
BCLKA
BCLKB
BCLKC
BCLKD
1
O Baud Rate Generator Output. The baud rate generator clock output is internally con-
30
nected to the RCLK input. This pin provides the 16X clock of the selected data rate from
51
the baud rate generator.
80
16/68#
36
Intel or Motorola Bus Select (input with internal pull-up).
When 16/68# pin is at logic 1, 16 or Intel Mode, the device will operate in the Intel bus
type of interface.
When 16/68# pin is at logic 0, 68 or Motorola mode, the device will operate in the Motor-
ola bus type of interface.
CLKSEL
35
I Baud-Rate-Generator Input Clock Prescaler Select for channels A-D. This input is only
sampled during power up or a reset. Connect to VCC for divide by 1 and GND for divide
by 4. MCR[7] can override the state of this pin following a reset or initialization. See MCR
bit-7 and Figure 5 in the Baud Rate Generator section.