DC ELECTRICAL CHARACTERISTICS 1
( -55°C < TC < +125°C) (T C = -55°C to +125°C for "C" screening and -40°C to +125°C for "W" screening)
SYMBOL
PARAMETER
CONDITION
MIN
MAX
VT+ Schmitt Trigger, positive going threshold2 VDD from 3.00 to 5.5
.7VDD
VT-
Schmitt Trigger, negative going threshold2 VDD from 3.00 to 5.5
.3VDD
VH1 Schmitt Trigger range of hysteresis10
VDD from 4.5 to 5.5
0.6
VH2 Schmitt Trigger range of hysteresis10
VDD from 3.00 to 3.6
0.4
IIN
Input leakage current10
IOZ
Three-state output leakage current10
ICS
Cold sparing leakage current3
IOS1
Short-circuit output current 6, 11
IOS2
Short-circuit output current 6, 11
VOL1 Low-level output voltage4, 10
VOL2 Low-level output voltage4, 10
VDD from 3.6 to 5.5
VIN = VDD or VSS
VDD from 3.6 to 5.5
VIN = VDD or VSS
VIN = 5.5
VDD = V SS
VO = VDD or VSS
VDD from 4.5 to 5.5
VO = VDD or VSS
VDD from 3.00 to 3.6
IOL= 8mA
IOL= 100µA
VDD = 4.5
IOL= 8mA
IOL= 100µA
VDD = 3.00
-1
3
-1
3
-1
5
-200
200
-100
100
0.4
0.2
0.5
0.2
VOH1 High-level output voltage4, 10
VOH2 High-level output voltage4, 10
IOH= -8mA
IOH= -100µA
VDD = 4.5
IOH= -8mA
IOH= -100µA
VDD = 3.00
VDD - 0.7
VDD - 0.2
VDD - 0.9
VDD - 0.2
UNIT
V
V
V
V
µA
µA
µA
mA
mA
V
V
V
V
5