Specifications HS-80C86RH
TABLE 3A. ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
LIMITS
PARAMETERS
SYMBOL
CONDITIONS
TEMPERATURE
MIN
MAX
UNITS
TIMING RESPONSES
Address Hold Time
TCLAX VDD = 4.75V and 5.25V -35oC < TA < +125oC
10
Min and Max Mode
-
ns
Address Float Delay (Note 2)
TCLAZ VDD = 4.75V and 5.25V -35oC < TA < +125oC
TCLAX
80
ns
Min and Max Mode
Data Valid Delay
TCLDV VDD = 4.75V and 5.25V -35oC < TA < +125oC
10
Min and Max Mode
110
ns
Data Hold Time
TCLDX2 VDD = 4.75V and 5.25V -35oC < TA < +125oC
10
Min and Max Mode
-
ns
Data Hold Time After WR
TWHDX VDD = 4.75V and 5.25V -35oC < TA < +125oC TCLCL - 30
-
ns
Min Mode
Status Float Delay (Note 2)
TCHSZ VDD = 4.75V and 5.25V -35oC < TA < +125oC
-
Max Mode
80
ns
Address Float to Read Active
TAZRL VDD = 4.75V and 5.25V -35oC < TA < +125oC
0
(Note 2)
Min and Max Mode
-
ns
NOTES:
1. All measurements referenced to device ground.
2. Output drivers disabled. Bus hold circuitry still active.
3. The parameters are controlled via design or process parameters and are not directly tested. These parameters are characterized upon
initial design release and upon design changes which would affect these characteristics.
TABLE 3B. ELECTRICAL PERFORMANCE CHARACTERISTICS
Timing Signals at HS-82C85RH or 82C88 for Reference Only.
PARAMETERS
SYMBOL
CONDITIONS
TEMPERATURE
RDY Setup Time into HS-82C85RH (Note 1)
RDY Hold Time into HS-82C85RH (Note 1)
Command Active Delay
Command Inactive
Status Valid to ALE High
Status Valid to MCE High
CLK Low to ALE Valid
CLK Low to MCE High
ALE Inactive Delay
MCE Inactive Delay
Control Active Delay
Control Inactive Delay
TR1VCL Min and Max Mode
TCLR1X Min and Max Mode
TCLML Max Mode Only
TCLMH Max Mode Only
TSVLH Max Mode Only
TSVMCH Max Mode Only
TCLLH Max Mode Only
TCLMCH Max Mode Only
TCHLL Max Mode Only
TCLMCL Max Mode Only
TCVNV Max Mode Only
TCVNX Max Mode Only
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
-35oC < TA < +125oC
NOTE:
1. Setup requirement for asynchronous signal only to guarantee recognition at next CLK.
LIMITS
MIN MAX UNITS
35 -
ns
0-
ns
5 35
ns
5 35
ns
- 20
ns
- 30
ns
- 20
ns
- 25
ns
4 18
ns
- 15
ns
5 45
ns
10 45
ns
TABLE 4. POST 100K RAD ELECTRICAL PERFORMANCE CHARACTERISTICS
NOTE: See 25oC limits in Table 1 and Table 2 for Post RAD limits (Subgroups 1, 7 and 9).
Spec Number 518055