datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

CH2165(2003) Ver la hoja de datos (PDF) - Cermetek Microelectronics

Número de pieza
componentes Descripción
Lista de partido
CH2165
(Rev.:2003)
Cermetek
Cermetek Microelectronics Cermetek
CH2165 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Cermetek Microelectronics, Inc.
High Speed Internet Modem Family
Table 2. Summary of Available @T® Commands By Category for CH2165.
Command Query
Description
@T[M][=n]
@T[D][=n]
@T[D][=0]
@T[N][=n]
@T[PI][=n]
@T[PM][=n]
@T[UI][=n]
@T[UM][=n]
@T[ED][=n]
@T[EO][]
@T[EQ][]
@T[ER][=n]
@T[ES][]
@T[BC][=n]
@T[BE][=n]
@T[BT][=n]
@T[M][?]
-----
-----
@T[N][?]
@T[PI][?]
@T[PM][?]
@T[UI][?]
@T[UM][?]
-----
-----
-----
-----
-----
@T[BC][?]
@T[BE][?]
@T[BT][?]
Email Message Management
Enter email message, n. Length limited 100K bytes per message. All valid ASCIII
characters allowed. Use CNTRL D to terminate message entry. Message is
maintained in dynamic RAM until stored in Static Memory using the @TW command.
Send Email Message
Dialup ISP and send email message, n. Use internet TO, FROM, REPLY, and
ERROR TO addresses contained within message n. Use the POP dialup phone
number currently active.
Dialup ISP. Use internet TO, FROM, REPLY, and ERROR TO addresses currently
active. Use the POP dialup phone number currently active. Enter Streaming Email
data entry mode. Terminate data entry using <CR>.<CR>. Message is sent
immediately following receipt of <CR>.<CR> sequence.
POP Access Dialup Phone Number
Set POP dialup access dial-up phone number string, n.
supported:
Each comma will cause a 2 second delay.
Use a dash as a delimiter. Dashes are ignored.
Special characters
Password
Set ISP Login password, n.
Set POP3 email retrieve password, n.
Username
Set ISP Login username, n.
Set POP3 email retrieve username, n.
POP3 Retrieval
Delete message number, n.
Open POP3 mailbox.
Quit POP3 mailbox activity and close POP3 server.
Retrieve message number, n.
Inventory all messages currently on POP3 server and list message number and
subject line.
DCE and DTE Attributes
Select DCE Baud rate, n. Allowable values:
n=57600.
n=38400.
n=19200.
n=9600.
n=4800.
n=2400.
By default, if no value is specified, the CH2165 will automatically determine the
maximum baud rate supported by the PSTN connection. This is referred to as auto-
bauding.
Toggle DTE echo.
n=on Enable DTE echo (default).
n=off Disable DTE echo.
Select DTE Baud rate, n. Allowable values:
n=57600.
n=38400.
n=19200. (Default).
n=9600.
n=4800.
n=2400.
2003 Cermetek Microelectronics, Inc.