datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

M66011FP Ver la hoja de datos (PDF) - MITSUBISHI ELECTRIC

Número de pieza
componentes Descripción
Lista de partido
M66011FP
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
M66011FP Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MITSUBISHI DIGITAL ASSP
M66011FP
SERIAL BUS CONTROLLER
3. Serial data input/output operation
A cycle of 16-bit serial output data setting and serial data
communication starts with a write access given by micro-
computer to transmission shift registers in M66011.
M66011 has two 8-bit shift registers, on for upper byte
(SRU), the other for lower byte (SRL). If the CS status rises
from “L” to “H” after a write access is given to SRL, serial
data communication is started. SRU 8-bit data and SRL, 8-
bit data are output in series in this order. Output of each
data starts from its most significant bit.
At the CS rise edge, busy flag in M66011 is set, and OE
output shifts from “H” to “L”. Shift clock SCLK and serial
data SOUT are then output.
At SCLK fall edges, serial output shift register executes
shifting operation, and data on shift register is output in se-
ries from pin SOUT. Serial input data from pin SIN is taken
into input shift register at SCLK 8T thru 16T rise edges.
However, data taken in at 8T rise edge is processed as ac-
knowledge bit, while data taken in at 9T thru 16T rise
edges are processed as data bits.
After the SCLK 16T rise edge, the status of SOUT and OE
shifts to “H” after one bit’s delay of SCLK, and busy flag is
reset. When interrupt output is being set to enable, INT
output is set.
(Remarks)
(1) If CS rises after write operation is executed on SRL only
and not on SRU, SRU data is unstable.
(2) When write operations executed on SRL, M66011 be-
comes ready for start of serial communication and stands
by for detection of CS rise. However, if a read access is
given after data is written on SRL while CS is maintained
on “L” level, this standby status is canceled. To resume se-
rial communication in this case, rewrite data on SRL and
raise CS.
SRL
write operation
CS
Busy flag
(in M66011)
OE
INT
Serial communication period
SCLK
SOUT
SIN
1T 2T
8T 9T
16T
D015 D014 D013 D012 D011 D010 D09 D08 D07 D06 D05 D04 D03 D02 D01 D00
(D7U)
(D0U) (D7L)
(D0L)
ACK DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
Serial Communication Timing Chart
5