datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

HLMP-Q106 Ver la hoja de datos (PDF) - HP => Agilent Technologies

Número de pieza
componentes Descripción
Lista de partido
HLMP-Q106 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
Absolute Maximum Ratings at TA = 25°C
Parameters
DC Forward Current[1]
Peak Forward Current[2]
Average Forward Current[2,3]
Transient Forward Current (10 µs Pulse)[4]
Power Dissipation
Reverse Voltage
Junction Temperature
Operating Temperature
Storage Temperature
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
Reflow Soldering Temperature
Title
50 mA
300 mA
30 mA
500 mA
100 mW
5V
110°C
-55°C to +100°C
-55°C to +100°C
260°C for 5 seconds
260°C for 20 seconds
Notes:
1. Derate linearly as shown in Figure 6.
2. Refer to Figure 7 to establish pulsed operating conditions.
3. Maximum IAVG at f = 1 kHz, DF = 10%.
4. The transient peak current is the maximum non-recurring peak current the device can withstand
without damaging the LED die and wire bonds. It is not recommended that the device be
operated at peak currents above the Absolute Maximum Peak Forward Current.
Optical Characteristics at TA = 25°C
Part Number
HLMP-
Luminous Intensity
IV (mcd)
@ 20 mA[1]
Min.
Typ.
Q106-R00xx 100
400
Q102-N00xx 25
100
P106-Q00xx 63
130
Total Flux
fV (mlm)
@ 20 mA[2]
Typ.
280
-
280
Peak
Wavelength
lpeak (nm)
Typ.
654
654
654
Color, Dominant
Wavelength
ld[3] (nm)
Typ.
644
644
644
Viewing Angle
2q1/2
Degrees[4]
Typ.
15
35
75
Luminous
Efficacy
hv[5]
(lm/w)
85
85
85
Optical Characteristics at TA = 25°C
Part Number
(Low Current)
HLMP-
Luminous Intensity
IV (mcd)
@ 0.5 mA[1]
Min.
Typ.
Q156-H00xx 2.5
7
Q152-G00xx 1.6
2
P156-EG0xx 0.63
2
Total Flux
fV (mlm)
@ 0.5 mA[2]
Typ.
10.5
-
10.5
Peak
Wavelength
lpeak (nm)
Typ.
654
654
654
Color, Dominant
Wavelength
ld[3] (nm)
Typ.
644
644
644
Viewing Angle
2f1/2
Degrees[4]
Typ.
15
35
75
Luminous
Efficacy
hv[5]
(lm/w)
85
85
85
Notes:
1. The luminous intensity, Iv, is measured at the mechanical axis of the lamp package. The actual peak of the spatial radiation pattern may not be
aligned with this axis.
2. fv is the total luminous flux output as measured with an integrating sphere.
3. The dominant wavelength, ld, is derived from the CIE Chromaticity Diagram and represents the color of the device.
4. q1/2 is the off-axis angle where the liminous intensity is 1/2 the peak intensity.
5. Radiant intensity, Iv, in watts/steradian, may be calculated from the equation Iv = Iv/hv, where Iv is the luminous intensity in candelas and hv is the
luminous efficacy in lumens/watt.