MSM54V24632A
¡ Semiconductor
Notes : 1. AC measurements assume tT = 1 ns.
2. The reference level for timing of input signals is 1.4 V.
3. Output load.
Output
Z = 50 W
1.4 V
50 W
30 pF
4. An access time is measured at 1.4 V.
5. If tT is longer than 1ns, the reference level for timing of input signals is VIH and VIL.
11