datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

MM1378 Ver la hoja de datos (PDF) - Mitsumi

Número de pieza
componentes Descripción
Lista de partido
MM1378 Datasheet PDF : 4 Pages
1 2 3 4
MITSUMI
Voltage and Current Control (dual op-amp and shunt regulator) (quad op-amp and shunt regulator) MM1377, 1378
Absolute Maximun Ratings
Item
Storage temperature
Operating temperature
Power supply voltage
Allowable loss
Symbol
TSTG
TOPR
VCC max.
PD
Ratings
-40~+125
-20~+85
-0.3~+24
300 (MM1377)
350 (MM1378)
Units
°C
°C
V
mW
Recommended Operating Conditions
Item
Symbol
Ratings
Operating temperature
TOPR
-15~+80
Operating voltage
VOPR
* +2~+20
*Minimum value of operating voltage is for amp unit only
Units
°C
V
Electrical Characteristics (Except where noted otherwise, VCC=5V, Ta=25°C)
Item
Symbol
Op-amp unit
Input offset voltage
VIO
Input offset current
IIO
Input bias current
IB
Common-mode input voltage range VI
Power supply current
ICC
Voltage gain
Output voltage L
Output voltage H
Common-mode signal rejection ratio
Power supply voltage rejection ratio
Output outflow current
Output inflow current
Shunt regulator
Reference voltage
Reference voltage fluctuation
within operating temperature range
Minimum cathode current
Dynamic impedance
AV
VOL
VOH
CMRR
PSRR
ISO
ISI
VREF
VREF
I min.
ZKA
Measurement conditions
Min. Typ. Max. Units
0.2 0.9 mV
Excluding amp A
5 50 nA
30 150 nA
Excluding amp A
0
VCC-1 V
RL=, for two circuits
RL=, for four circuits
MM1377
MM1378
0.6 1.0
mA
1.2 2.0
100
dB
RL=
10 100 mV
RL=
VCC-1.1 VCC-0.8
V
65 85
dB
65 100
dB
20 35
mA
10 20
mA
2.450 2.500 2.550 V
5 17 mV
0.4 1.0 mA
0.4 0.7

Share Link: 