SYMBOL
PCN
POLL
PRETRK
R
RCN
SC
SK
SRT
ST0
ST1
ST2
ST3
WGATE
Table 18 - Description of Command Symbols
NAME
DESCRIPTION
modified if OW is set to 1. OW id defined in the Lock command.
Present Cylinder The current position of the head at the completion of Sense Interrupt
Number
Status command.
Polling Disable
When set, the internal polling routine is disabled. When clear, polling
is enabled.
Precompensation Programmable from track 00 to FFH.
Start Track
Number
Sector Address
The sector number to be read or written. In multi-sector transfers,
this parameter specifies the sector number of the first sector to be
read or written.
Relative Cylinder Relative cylinder offset from present cylinder as used by the Relative
Number
Seek command.
Number of Sectors The number of sectors per track to be initialized by the Format
Per Track
command. The number of sectors per track to be verified during a
Verify command when EC is set.
Skip Flag
When set to 1, sectors containing a deleted data address mark will
automatically be skipped during the execution of Read Data. If Read
Deleted is executed, only sectors with a deleted address mark will be
accessed. When set to "0", the sector is read or written the same as
the read and write commands.
Step Rate Interval
The time interval between step pulses issued by the FDC.
Programmable from 0.5 to 8 milliseconds in increments of 0.5 ms at
the 1 Mbit data rate. Refer to the SPECIFY command for actual
delays.
Status 0
Status 1
Status 2
Registers within the FDC which store status information after a
command has been executed. This status information is available to
the host during the result phase after command execution.
Status 3
Write Gate
Alters timing of WE to allow for pre-erase loads in perpendicular
drives.