Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature: 0 ° to +40 °C ambient
Storage temperature: -40 °C to +85 °C
Electromagnetic
susceptibility:
Humidity:
Designed to meet EN55024
Operating; non-condensing 5% to 95% RH
Vibration:
Frequency/PSD: 5 - 350 Hz
0.0001 g2/Hz
350 - 500 Hz - 6dB/Oct.
500 Hz
0.00005g2/Hz
Acceleration: 0.21 gRMS
Duration:
20 min per second
AC Plug Configuration
U.S. 2-prong
US
Europe 2-prong
EU
United Kingdom 3-prong UK
Australia 2-prong
AU
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
Minimum
Load
Maximum
Load
Regulation2
Ripple
P/P (PARD)3
DA12-120US-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-120EU-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-120UK-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-120AU-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-050US-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
DA12-050EU-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
DA12-050UK-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
DA12-050AU-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3­. Peak-to-peak with 20 mHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4­. Power supplies will operate with no-load.
Mechanical Drawings
DA12-XXXUS-M
59”
(1500)
Rev. 7.8.09_105
DA12-M Series
 of 4
2.36”
(60)
(-)
(+)
CONNECTOR PIN-OUT DETAIL

Share Link: 