datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

DHR500C5(2006) Ver la hoja de datos (PDF) - LEM Industrial

Número de pieza
componentes Descripción
Lista de partido
DHR500C5
(Rev.:2006)
LEM
LEM Industrial LEM
DHR500C5 Datasheet PDF : 3 Pages
1 2 3
Dimensions DHR-C5 (in mm. 1 mm = 0.0394 inch)
25
70
60
2 2.2 8
6 .80
90
4
15
7
6
78
Connections
Wires up to 2 mm
DFHeRm-aCle5/c1o0nnector provided (screw terminals)
DHR
24 VDC Power
(+)
(-)
Output Connector
1(Vcc) 2(NC) 3(Vout) 4(GND)
10k
(-)
(+)
Load
(Controller, meter etc)
+24VDC
Is
OUT
Ip
GND
Mechanical characteristics
General tolerance
±1 mm
Primary aperture
32.0 mm
Panel mounting
4 holes 4.6 mm
Distance between holes
70.0 mm & 78 mm
(see above dimensions)
For panel mounting, replace M4 screws by new one (not supplied)
with appropriate length to panel´s thickness.
Remarks
VOUT is positive when IP flows in the direction of the arrow.
The return busbar and primary conductor elbow must be located
at least at 2.5 x window length more far away from the transducer
case.
The temperature of the primary busbar can not exceed 90 °C.
Dynamic performances are the best with a primary busbar
completely filling the primary aperture.
This is a standard model. For different versions (supply voltages,
different outputs, bidirectional measurements...), please
contact us.
061128/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 3/3
www.lem.com

Share Link: 