IDT54/74FCT162511AT/CT
FAST CMOS 16-BIT REGISTERED/LATCHED TRANSCEIVER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Industrial: TA = –40°C to +85°C, VCC = 5.0V ±10%; Military: TA = –55°C to +125°C, VCC = 5.0V ±10%
Symbol
Parameter
Test Conditions(1)
Min. Typ.(2)
Max.
Unit
VIH
Input HIGH Level
Guaranteed Logic HIGH Level
2
V
VIL
Input LOW Level
Guaranteed Logic LOW Level
0.8
V
IIH
Input HIGH Current (Input pins)(5) VCC = Max.
VI = VCC
±1
µA
Input HIGH Current (I/O pins)(5)
IIL
Input LOW Current (Input pins)(5)
VI = GND
±1
±1
Input LOW Current (I/O pins)(5)
±1
IOZH
High Impedance Output Current VCC = Max.
IOZL
(3-State Output pins)(5)
VO = 2.7V
VO = 0.5V
±1
µA
±1
VIK
Clamp Diode Voltage
VCC = Min., IIN = –18mA
–0.7
–1.2
V
IOS
Short Circuit Current
VCC = Max., VO = GND(3)
–80
–140
–250
mA
VH
Input Hysteresis
ICCL
Quiescent Power Supply Current VCC = Max.
ICCH
VIN = GND or VCC
ICCZ
100
mV
5
500
µA
OUTPUT DRIVE CHARACTERISTICS
Symbol
Parameter
Test Conditions(1)
Min. Typ.(2) Max. Unit
IODL
Output LOW
(I/O pins)
VCC = 5V, VIN = VIH or VIL, VO = 1.5V(3)
60 115 200 mA
Current
(Open Drain)
— 250 — mA
IODH Output HIGH Current
VCC = 5V, VIN = VIH or VIL, VO = 1.5V(3)
–60 –115 –200 mA
IOFF Output Power Off Leakage Current
(Open Drain)(5)
VCC = 0, VO 5.5V
±1 µA
VOH Output HIGH Voltage (I/O pins)
VCC = Min.
IOH = –16mA MIL
2.4
3.3
V
VIN = VIH or VIL
IOH = –24mA IND
VOL OutputLOW
(I/O pins)
VCC = Min.
IOL = 16mA MIL
0.3 0.55 V
Voltage
VIN = VIH or VIL
IOL = 24mA IND
(Open Drain)
IOL = 48mA MIL
0.3 0.55 V
IOL = 64mA IND
NOTES:
1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
4. Duration of the condition can not exceed one second.
5. The test limit for this parameter is ±5µA at TA = –55°C.