IDT54/74FCT162511AT/CT
FAST CMOS 16-BIT REGISTERED/LATCHED TRANSCEIVER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
(PROPAGATION DELAYS)
FCT162511AT
FCT162511CT
Ind.
Mil.
Ind.
Mil.
Symbol
Parameter
Condition(1) Min.(2) Max. Min.(2) Max. Min.(2) Max. Min.(2) Max. Unit
tPLH Propagation Delay, PAx to PBx
CL = 50pF 1.5
5
1.5
5.3
1.5
4.2 1.5
4.5
ns
tPHL Ax to Bx or Bx to Ax, PBx to PAx
RL = 500Ω
tPLH
Propagation Delay
GEN/CHK LOW
tPHL
Ax to PBx
1.5
7.5
1.5
8
1.5
6.5 1.5
6.8
ns
tPLH(3) PropagationDelay
1.5
9
1.5
9
1.5
7.5 1.5
7.8
ns
tPHL
Ax to PERB, PAx to PERB
1.5
8
1.5
8
1.5
6.5 1.5
6.8
ns
tPLH(3) PropagationDelay
1.5
9
1.5
9
1.5
7.5 1.5
7.8
ns
tPHL
Bx to PERA, PBx to PERA
1.5
8
1.5
8
1.5
6.5 1.5
6.8
ns
tPLH PropagationDelay
tPHL LEBA to Ax and PAx
1.5
5.6
1.5
6
1.5
5.3 1.5
5.5
ns
LEAB to Bx and PBx
tPLH(3)
tPHL
Propagation Delay
LEBA to PERA, LEAB to PERB
1.5
7
1.5
7
1.5
6
1.5
6.3
ns
1.5
6
1.5
6
1.5
5
1.5
5.3
ns
tPLH PropagationDelay
tPHL CLKBA to Ax and PAx
1.5
5.6
1.5
6
1.5
5.3 1.5
5.5
ns
CLKAB to Bx and PBx
tPLH(3)
tPHL
Propagation Delay
CLKBA to PERA
CLKAB to PERB
1.5
7
1.5
7
1.5
6
1.5
6.3
ns
1.5
6
1.5
6
1.5
5
1.5
5.3
ns
tPZH OutputEnableTime
tPZL
OEBA to Ax and PAx
OEAB to Bx and PBx
1.5
6
1.5
6.5
1.5
5.6 1.5
5.8
ns
tPHZ OutputDisableTime
tPLZ
OEBA to Ax and PAx
OEAB to Bx and PBx
1.5
5.6
1.5
6
1.5
5.2 1.5
5.5
ns
tPLZ(3)
tPZL
tPLH(3)
Parity ERROR Enable
OEBA to PERA, OEAB to PERB
ODD/EVEN to PERx
1.5
6
1.5
6.3
1.5
6
1.5
6.3
ns
1.5
6
1.5
6.3
1.5
6
1.5
6.3
ns
1.5
10
1.5
10
1.5
10 1.5
10
ns
tPHL
tPLH
ODD/EVEN to PBx
tPHL
1.5
10
1.5
10
1.5
10 1.5
10
ns
1.5
10
1.5
10
1.5
10 1.5
10
ns
NOTES:
1. See test circuits and waveforms.
2. Minimum limits are guaranteed but not tested on Propagation Delays.
3. On Open Drain Outputs tPLH is measured at VOUT = VOL + 0.3V.
7