High-Linearity, 650MHz to 1000MHz Upconversion/
Downconversion Mixer with LO Buffer/Switch
AC ELECTRICAL CHARACTERISTICS (800MHz/900MHz CELLULAR BAND DOWNCON-
VERTER OPERATION)
(Typical Application Circuit, optimized for the 800MHz/900MHz cellular band (see Table 1), C1 = 82pF, C5 = 2pF, L1 and C4 not
used, VCC = 4.75V to 5.25V, RF and LO ports driven from 50sources, PLO = -3dBm to +3dBm, PRF = 0dBm, fRF = 815MHz to
1000MHz, fLO = 960MHz to 1180MHz, fIF = 160MHz, fLO > fRF, TC = -40°C to +85°C, unless otherwise noted. Typical values are at
VCC = 5V, PRF = 0dBm, PLO = 0dBm, fRF = 910MHz, fLO = 1070MHz, fIF = 160MHz, TC = +25°C, unless otherwise noted.) (Note 8)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Conversion Loss
Conversion Loss Flatness
Conversion Loss Variation Over
Temperature
Input 1dB Compression Point
Input Third-Order Intercept Point
Input IP3 Variation Over
Temperature
2LO - 2RF Spurious Response at IF
LC
P1dB
IIP3
IIP3
2x2
Flatness over any one of three frequency
bands (fIF = 160MHz):
fRF = 827MHz to 849MHz
fRF = 869MHz to 894MHz
fRF = 880MHz to 915MHz
TC = +25°C to -40°C
TC = +25°C to +85°C
(Note 9)
fRF1 = 910MHz, fRF2 = 911MHz,
PRF = 0dBm/tone, fLO = 1070MHz,
PLO = 0dBm, TC = +25°C (Note 10)
TC = +25°C to -40°C
TC = +25°C to +85°C
7.0
±0.18
-0.3
0.2
24
29
33
0.3
-0.3
65
dB
dB
dB
dBm
dBm
dB
dBc
3LO - 3RF Spurious Response at IF
3x3
75
dBc
Noise Figure
NF Single sideband
7.0
dB
Noise Figure Under Blocking
(Note 11)
LO1-to-LO2 Isolation (Note 10)
Maximum LO Leakage at RF Port
Maximum LO Leakage at IF Port
LO Switching Time
PBLOCKER = +8dBm
18
PBLOCKER = +12dBm
22
LO2 selected, PLO = +3dBm, TC = +25°C
42
51
LO1 selected, PLO = +3dBm, TC = +25°C
42
49
PLO = +3dBm
-27
PLO = +3dBm
-35
50% of LOSEL to IF, settled within 2 degrees
50
dB
dB
dBm
dBm
ns
Minimum RF-to-IF Isolation
45
dB
RF Port Return Loss
17
dB
LO Port Return Loss
LO1/LO2 port selected, LO2/LO1, RF, and IF
terminated into 50
28
dB
LO1/LO2 port unselected, LO2/LO1, RF, and
IF terminated into 50
30
IF Port Return Loss
LO driven at 0dBm, RF terminated into 50
17
dB
_______________________________________________________________________________________ 3