SiGe, High-Linearity, 2300MHz to 4000MHz
Upconversion/Downconversion Mixer with LO Buffer
3.3V SUPPLY AC ELECTRICAL CHARACTERISTICS (DOWNCONVERTER MODE,
fRF = 3100MHz to 3900MHz, LOW-SIDE LO INJECTION)
(Typical Application Circuit with tuning elements outlined in Table 1, RF and LO ports are driven from 50I sources. Typical values
are at VCC = 3.3V, PRF = 0dBm, PLO = 0dBm, fRF = 3500MHz, fLO = 3200MHz, fIF = 300MHz, TC = +25NC, unless otherwise noted.)
(Note 6)
PARAMETER
Conversion Loss
Loss Variation vs. Frequency
SYMBOL
LC
DLC
CONDITIONS
fRF = 3100MHz to 3900MHz, over any
100MHz band
MIN TYP MAX UNITS
7.7
dB
0.1
dB
Conversion Loss Temperature
Coefficient
Input Compression Point
Third-Order Input Intercept
Point
TCCL
IP1dB
IIP3
fRF = 3100MHz to 3900MHz,
TC = -40NC to +85NC
(Note 9)
fRF1 - fRF2 = 1MHz, PRF = 0dBm per tone
0.009
19.5
29.5
dB/NC
dBm
dBm
Third-Order Input Intercept
Variation Over Temperature
Noise Figure
Noise Figure Temperature
Coefficient
2RF - 2LO Spurious Rejection
3RF - 3LO Spurious Rejection
RF Input Return Loss
NFSSB
TCNF
2x2
3x3
RLRF
fRF1 - fRF2 = 1MHz, PRF = 0dBm per tone,
TC = -40NC to +85NC
Single sideband, no blockers present
Single sideband, no blockers present,
TC = -40NC to +85NC
fSPUR = fLO +
150MHz
fSPUR = fLO +
100MHz
PRF = -10dBm
PRF = 0dBm
PRF = -10dBm
PRF = 0dBm
LO on and IF terminated into a matched
impedance
±0.2
8.5
0.018
69
64
73.3
63.3
18
dB
dB
dB/NC
dBc
dBc
dB
LO Input Return Loss
RLLO
RF and IF terminated into a matched
impedance
19
dB
IF Output Impedance
ZIF
Nominal differential impedance at the IC’s
IF outputs
50
I
IF Output Return Loss
RF terminated into 50I, LO driven by a
RLIF
50I source, IF transformed to 50I using
external components shown in the Typical
14.5
dB
Application Circuit
RF-to-IF Isolation
LO Leakage at RF Port
2LO Leakage at RF Port
LO Leakage at IF Port
fRF = 3100MHz to 3900MHz,
PLO = +3dBm
fLO = 2800MHz to 3600MHz,
PLO = +3dBm
fLO = 2800MHz to 3600MHz,
PLO = +3dBm
fLO = 2800MHz to 3600MHz,
PLO = +3dBm
41
-30
-25.6
-27
dB
dBm
dBm
dBm
_______________________________________________________________________________________   5

Share Link: 