Stereo Volume Control
with Rotary Encoder Interface
PIN
1
2
3
4
5
6
7, 24
8
9
10
11
12
13
14
15
16
17
18–22
23
Pin Description
NAME
FUNCTION
VLOGIC
Digital Logic Power Supply. Bypass VLOGIC to ground with a 0.1µF capacitor as close to the device
as possible.
RENCODEA
RENCODEB
MUTE
Rotary Encoder Input A. With RENCODEB, this input provides the rotary encoder control for the
potentiometer (see Figure 1). RENCODEA is internally pulled up to VLOGIC with a 45kresistor.
Rotary Encoder Input B. With RENCODEA, this input provides the rotary encoder control for the
potentiometer (see Figure 1). RENCODEB is internally pulled up to VLOGIC with a 45kresistor.
Mute Input. Pull MUTE low to toggle the wiper between the mute setting (see Table 1) and the current
setting. MUTE is pulled up to VLOGIC with an internal 45kresistor.
MODE
Volume/Balance Control Input. Each high-to-low transition on MODE toggles between the volume and
balance modes. MODE is pulled high internally with a 45kresistor to VLOGIC. On power-up, the
MAX5440 is in volume-control mode.
SHDN
GND
H0
L0
W0
MIDBIAS
BIAS
VDD
VSS
W1
L1
H1
LEDIND0–
LEDIND4
Active-Low Shutdown Input. Drive SHDN low to place the device in shutdown mode. In shutdown
mode, the MAX5440 stores the last wipers settings. The wipers move to the L_ end of the resistor
string. Terminating shutdown mode restores the wipers to their previous settings.
Ground. Connect pins 7 and 24 together.
Potentiometer 0 High Terminal. H0 and L0 terminals can be reversed.
Potentiometer 0 Low Terminal. L0 and H0 terminals can be reversed.
Potentiometer 0 Wiper Buffered Output
Midbias Voltage Output. VMIDBIAS = (VDD + VSS) / 2.
Bias Generator Input. Bypass with a 1µF capacitor to system ground.
Analog Power Supply. Bypass VDD to ground with a 0.1µF capacitor as close to the device as
possible.
Negative Power Supply. Bypass VSS to ground with a 0.1µF capacitor as close to the device as
possible. Connect to GND for single-supply operation.
Potentiometer 1 Wiper Buffered Output
Potentiometer 1 Low Terminal. L1 and H1 terminals can be reversed.
Potentiometer 1 High Terminal. H1 and L1 terminals can be reversed.
LED Indicator Open-Drain Output 0 through LED Indicator Open-Drain Output 4. LEDIND0–LEDIND4 form a
bar graph indication of the current volume or balance. In volume mode, all LEDs off indicates mute and all
LEDs on indicates maximum volume. In balanced mode, LED2 on indicates centered or balanced.
MODEIND
Volume-Control/Balance-Control Mode Indicator Open-Drain Output. Connect to an LED through a
resistor to VLOGIC. When the LED is on, the MAX5440 is in balance-control mode. When the LED is
off, the MAX5440 is in volume-control mode.
6 _______________________________________________________________________________________