3-Pin, Ultra-Low-Power SC70/SOT
µP Reset Circuits
____________ Applications Information
Interfacing to µPs with
Bidirectional Reset Pins
Since the RESET output on the MAX6328/MAX6348 is
open drain, these devices interface easily with micro-
processors (µPs) that have bidirectional reset pins,
such as the Motorola 68HC11. Connecting the µP
supervisor’s RESET output directly to the microcon-
troller’s (µC’s) RESET pin with a single pull-up resistor
allows either device to assert reset (Figure 1).
Negative-Going VCC Transients
In addition to issuing a reset to the µP during power-up,
power-down, and brownout conditions, these devices
are relatively immune to short-duration, negative-going
VCC transients (glitches).
The Typical Operating Characteristics show the Maxi-
mum Transient Duration vs. Reset Threshold Overdrive
graph, for which reset pulses are not generated. The
graph shows the maximum pulse width that a negative-
going VCC transient may typically have when issuing a
reset signal. As the amplitude of the transient increas-
es, the maximum allowable pulse width decreases.
VCC
VCC
MAX6328
MAX6348
RESET
VCC
µP
MOTOROLA
RESET 68HCXX
INPUT
GND
GND
Figure 1. Interfacing to µPs with Bidirectional Reset Pins
Table 1. Factory-Trimmed Reset Thresholds
PART
SUFFIX
MAX632_ _R
22
MAX632_ _R
23
MAX632_ _R
24
MAX632_ _R
25
MAX632_ _R
26
MAX632_ _R
27
MAX632_ _R
28
MAX632_ _R
29
MAX632_ _R
30
MAX632_ _R
31
MAX634_ _R
33
MAX634_ _R
34
MAX634_ _R
35
MAX634_ _R
36
MAX634_ _R
37
MAX634_ _R
38
MIN
2.167
2.285
2.364
2.462
2.591
2.660
2.758
2.886
2.955
3.034
3.250
3.349
3.447
3.546
3.644
3.743
RESET THRESHOLD VOLTAGE, VTH (V)
TA = +25°C
TYP
MAX
TA = -40°C to +85°C
MIN
MAX
2.200
2.233
2.145
2.250
2.320
2.355
2.262
2.375
2.400
2.436
2.340
2.460
2.500
2.537
2.437
2.562
2.630
2.669
2.564
2.696
2.700
2.741
2.633
2.768
2.800
2.842
2.730
2.870
2.930
2.974
2.857
3.000
3.000
3.045
2.925
3.075
3.080
3.126
3.003
3.150
3.300
3.350
3.217
3.383
3.400
3.451
3.315
3.485
3.500
3.552
3.412
3.587
3.600
3.654
3.510
3.690
3.700
3.755
3.607
3.792
3.800
3.857
3.705
3.895
Factory-trimmed reset thresholds are available in approximately 100mV increments with a 1.5% room-temperature variance.
4 _______________________________________________________________________________________