ADVANCE INFORMATION
MK2042-01
I CR O C LOC K
Communications Clock Monitor
Electrical Specifications
Parameter
Conditions
ABSOLUTE MAXIMUM RATINGS (Note 1)
Supply Voltage, VDD
Referenced to GND
Inputs and Clock Outputs
Ambient Operating Temperature
Soldering Temperature
Max of 10 seconds
Storage Temperature
DC CHARACTERISTICS (VDD = 3.3 V unless noted)
Operating Voltage, VDD
Input High Voltage, VIH (Note 2)
INA, INB
Input Low Voltage, VIL (Note 2)
INA, INB
Input High Voltage, VIH
Input Low Voltage, VIL
Output High Voltage, VOH, CMOS level
IOH=-4 mA
Output High Voltage, VOH
IOH=-8 mA
Output Low Voltage
IOL=8 mA
Operating Supply Current, IDD
No Load, VDD=3.3 V
Short Circuit Current
Each output
Input Capacitance
AC CHARACTERISTICS (VDD = 3.3 V unless noted)
Input Frequency, External Mode
INA, INB, REFIN
Input Clock Pulse Width
CLKOUT Settling Time
After SELB change
Output Clock Rise Time
0.8 to 2.0 V
Output Clock Fall Time
2.0 to 0.8 V
Output Clock Duty Cycle, High Time
At VDD/2
Minimum
-0.5
-40
-65
3.14
(VDD/2)+1
2
VDD-0.4
2.4
0
4
40
Typical
5
±50
7
Maximum
7
VDD+0.5
85
250
150
5.25
(VDD/2)-1
0.8
0.4
100
1
1.5
1.5
60
Units
V
V
°C
°C
°C
V
V
V
V
V
V
V
V
mA
mA
pF
MHz
ns
ms
ns
ns
%
Notes:
1. Stresses beyond those listed under Absolute Maximum Ratings could cause permanent damage to the device. Prolonged exposure
to levels above the operating limits but below the Absolute Maximums may affect device reliability.
2. Switching occurs nominally at VDD/2.
3: The phase relationship between input and output clocks can change at power up or when switching between INA and INB.
EXTERNAL COMPONENT SELECTION
The MK2042-01 requires a minimum number of external components for proper operation. A decoupling
capacitor of 0.01µF must be connected between VDD and GND, pins 15 and 10. This capacitor should be
as close to the chip as possible. A series termination resistor of 33 may be used on CLKOUT with traces
longer than 1 inch (assuming 50 traces). In applications where the HIGH and LOW outputs are
connected to the MK2049-xx, 10 kresistors should be used on each of those outputs.
MDS 2042-01
3
Revision 102600
Printed 11/15/00
Integrated Circuit Systems, Inc. • 525 Race Street • San Jose • CA • 95126 • (408)295-9800tel• www.icst.com