datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

PI74FCT163244 Ver la hoja de datos (PDF) - Pericom Semiconductor Corporation

Número de pieza
componentes Descripción
Lista de partido
PI74FCT163244
PERICOM
Pericom Semiconductor Corporation PERICOM
PI74FCT163244 Datasheet PDF : 5 Pages
1 2 3 4 5
PI74FCT163244
1122334455667788990011223344556677889900112233445566778899001122112233445566778899001122334455667788990011223344556677889900112211223344556677889900112233445566778899001122334435566.77388V99001112211622-33B445566I77T889900B1122U3344F5566F7788E9900R1122/33L4455I66N778899E0011D221122R3344I55V6677E889900R1122
Power Supply Characteristics
Parameters Description
ICC
ICC
ICCD
Quiescent Power Supply Current
Quiescent Power Supply Current
TTL Inputs HIGH
Dynamic Power Supply(4)
IC
Total Power Supply
Current(6)
Test Conditions(1)
Min. Typ.(2) Max.
VCC = Max.
VCC = Max.
VIN = GND or VCC
VIN = VCC – 0.6V(3)
0.1 10
2.0 30
Units
µA
µA
VCC = Max.,
Outputs Open
XOE = GND
One Bit Toggling
50% Duty Cycle
VCC = Max.,
Outputs Open
fI = 10 MHZ
50% Duty Cycle
XOE = GND
One Bit Toggling
VCC = Max.,
Outputs Open
fI = 2.5 MHZ
50% Duty Cycle
XOE = GND
16 Bits Toggling
VIN = VCC
VIN = GND
VIN = VCC – 0.6V
VIN = GND
VIN = VCC – 0.6V
VIN = GND
50 75 µA/
MHz
0.5 0.8 mA
2.0 3.3(5)
Notes:
1. For Max. or Min. conditions, use appropriate value specified under Electrical Characteristics for the applicable device.
2. Typical values are at Vcc = 3.3V, +25°C ambient.
3. Per TTL driven input; all other inputs at Vcc or GND.
4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations.
5. Values for these conditions are examples of the Icc formula. These limits are guaranteed but not tested.
6. IC =IQUIESCENT + IINPUTS + IDYNAMIC
IC = ICC + ICC DHNT + ICCD (fCP/2 + fINI)
ICC = Quiescent Current (ICCL, ICCH and ICCZ)
ICC = Power Supply Current for a TTL High Input
DH = Duty Cycle for TTL Inputs High
NT = Number of TTL Inputs at DH
ICCD = Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
fCP = Clock Frequency for Register Devices (Zero for Non-Register Devices)
NCP = Number of Clock Inputs at fCP
fI = Input Frequency
NI = Number of Inputs at fI
All currents are in milliamps and all frequencies are in megahertz.
4
PS2052B 01/18/99

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]