Data Sheet
TABLE 3: OPERATION MODES SELECTION
Mode
Read
Byte-Program
Sector-Erase
Standby
Write Inhibit
Software Chip-Erase
Product Identification
Hardware Mode
CE#
VIL
VIL
VIL
VIH
X
X
VIL
OE#
VIL
VIH
VIH
X1
VIL
X
VIH
VIL
VIL
Software Mode
SDP Enable & Disable Mode
Reset
VIL
VIL
VIL
VIL
VIL
VIH
1. X can be VIL or VIH, but no other value.
4 Mbit SuperFlash EEPROM
SST28SF040A / SST28VF040A
WE#
VIH
VIL
VIL
X
X
VIH
VIL
DQ
DOUT
DIN
DIN
High Z
High Z/ DOUT
High Z/ DOUT
DIN
VIH Manufacturer’s ID (BFH)
Device ID (04H)
VIH
VIH
VIL
Address
AIN
AIN, See Table 4
AIN, See Table 4
X
X
X
See Table 4
A18-A1=VIL, A9=VH, A0=VIL
A18-A1=VIL, A9=VH, A0=VIH
See Table 4
See Table 4
See Table 4
T3.4 310
TABLE 4: SOFTWARE COMMAND SUMMARY
Command Summary
Sector-Erase
Byte-Program
Chip-Erase6
Reset
Read-ID
Software Data Protect
Software Data Unprotect
Required
Cycle(s)
2
2
2
1
2
7
7
Setup Command Cycle
Type1
Addr2,3
Data4
W
X
20H
W
X
10H
W
X
30H
W
X
FFH
W
X
90H
R
8
R
9
Execute Command Cycle
Type1
Addr2,3
Data4
W
SA
D0H
W
PA
PD
W
X
30H
R
7
7
1. Type definition: W = Write, R = Read, X can be VIL or VIH, but no other value.
2. Addr (Address) definition: SA = Sector Address = A18-A8, sector size = 256 Bytes; A7-A0 = X for this command.
3. Addr (Address) definition: PA = Program Address = A18-A0.
4. Data definition: PD = Program Data, H = number in hex.
5. SDP = Software Data Protect mode using 7 Read Cycle Sequence.
a) Y = the operation can be executed with protection enabled
b) N = the operation cannot be executed with protection enabled
6. The Chip-Erase function is not supported on industrial temperature parts.
7. Address 0000H retrieves the Manufacturer’s ID of BFH and address 0001H retrieves the Device ID of 04H.
8. Refer to Figure 11 for the 7 Read Cycle sequence for Software-Data-Protect.
9. Refer to Figure 10 for the 7 Read Cycle sequence for Software-Data-Unprotect.
SDP5
N
N
N
Y
Y
T4.4 310
TABLE 5: MEMORY ARRAY DETAIL
Sector Select
A18 - A8
Byte Select
A7 - A0
T5.0 310