datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

GLT5160L16I-6TC Ver la hoja de datos (PDF) - G-Link Technology

Número de pieza
componentes Descripción
Lista de partido
GLT5160L16I-6TC
G-Link
G-Link Technology  G-Link
GLT5160L16I-6TC Datasheet PDF : 45 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Read
After tRCD from the bank activation, a READ command can be
issued. 1st output data is available after the CAS Latency from the
READ, followed by (BL-1) consecutive data when the Burst Length
is BL. The start address is specified by A[7:0], and the address
sequence of burst data is defined by the Burst Type. A READ com-
mand may be applied to any active bank, so the row precharge time
(tRP) can be hidden behind continuous output data (in case of BL =
4) by interleaving the dual banks. When A[10] is high at a READ
command, the auto-precharge (READA) is performed. Any com-
mand (READ, WRITE, PRE, ACT) to the same bank is inhibited till
the internal precharge is complete. The internal precharge start tim-
ing depends on CAS Latency. The next ACT command can be
issued after tRP from the internal precharge timing.
CLK
Command
A[9:0]
A[10]
BA
DQ
ACT
Xa
tRCD
REA
Ya
ACT
Xb
REA
PRE
Yb
Xa
0
Xb
0
0
0
0
1
1
0
Burst Length
Qa0
Qa1
Qa2
Qa3
Qb0
Qb1
Qb2
CAS Latency
Figure 4. Dual Bank Interleaving READ (BL=4, CL=3)
CLK
Command
A[9:0]
A[10]
BA
DQ
ACT
Xa
tRCD
READ A
Y
ACT
tRP
Xa
Xa
1
Xa
0
0
0
Qa0
Qa1
Qa2
Qa3
Internal Precharge begins
Figure 5. READ with Auto-Precharge (BL=4, CL=3)
CLK
Command
CL=3 DQ
CL=2 DQ
ACT
READ A
Qa0
Qa1
Qa2
Qa3
Qa0
Qa1
Qa2
Qa3
Internal Precharge Start Timing
Figure 6. READ Auto-Precharge Timing (BL=4)
G-LINK Technology
11
DEC. 2003 (Rev.2.4)

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]