MB39A108
(Continued)
( VCC = VCCO = 4 V, Ta = + 25 °C)
Parameter
Symbol Pin No.
Conditions
Value
Unit
Min Typ Max
PWM compara-
tor block (CH1)
[PWM Comp.1]
Threshold
voltage
VT0
VT100
33, 34 Duty cycle = 0%
33, 34 Duty cycle = 100%
0.35 0.4 0.45 V
0.85 0.9 0.95 V
PWM compara- Threshold
tor block
voltage
(CH2 to CH5)
[PWM Comp.2 to Maximum
PWM Comp.5] duty cycle
VT0
VT100
Dtr
29 to 32 Duty cycle = 0%
29 to 32 Duty cycle = 100%
29 to 32
CT = 100 pF,
RT = 6.8 kΩ
0.35 0.4 0.45 V
0.85 0.9 0.95 V
85
90
95 %
Output source
current
ISOURCE
Duty ≤ 5%
29 to 34 (t = 1/fosc × Duty)
OUT = 0 V
⎯ − 130 − 75 mA
Output block
(CH1 to CH5)
Output sink
current
[Drive1 to Drive5] Output on
resistor
Duty ≤ 5%
ISINK 29 to 34 (t = 1/fosc × Duty)
OUT = 4 V
ROH 29 to 34 OUT = − 15 mA
ROL 29 to 34 OUT = 15 mA
75
130 ⎯ mA
⎯
18
27 Ω
⎯
18
27 Ω
Dead time
tD1 33, 34 OUT2 − OUT1
tD2 33, 34 OUT1 − OUT2
⎯
50*
⎯ ns
⎯
50*
⎯ ns
Short-circuit
detection block
[SCP Comp.]
Threshold
voltage
Input bias
current
VTH
34
⎯
IB
10 − INS = 0 V
0.97 1.00 1.03 V
− 25 − 20 − 17 µA
Control block
(CTL, CTL3 to
CTL5)
Output on
condition
Output off
condition
VIH 6, 7 to 9 CTL, CTL3 to CTL5
VIL 6, 7 to 9 CTL, CTL3 to CTL5
1.5
⎯
11 V
0
⎯
0.5 V
[CTL, CHCTL]
ICTLH 6, 7 to 9 CTL, CTL3 to CTL5 = 3 V 5
30
60 µA
Input current
ICTLL 6, 7 to 9 CTL, CTL3 to CTL5 = 0 V ⎯
⎯
1 µA
General
Standby
current
ICCS
5 CTL, CTL3 to CTL5 = 0 V ⎯
0
ICCSO
35 CTL = 0 V
⎯
0
Power supply
current
ICC
5 CTL = 3 V
⎯
4
2 µA
1 µA
6 mA
* : Standard design value
11