datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

A1201 Ver la hoja de datos (PDF) - Allegro MicroSystems

Número de pieza
componentes Descripción
Lista de partido
A1201
Allegro
Allegro MicroSystems Allegro
A1201 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
A1201, A1202,
A1203, and A1204
Continuous-Time Bipolar Switch Family
OPERATING CHARACTERISTICS over full operating voltage and ambient temperature ranges, unless otherwise noted
Characteristic
Symbol
Test Conditions
Min. Typ. Max. Units
Electrical Characteristics
Supply Voltage1
Output Leakage Current
Output On Voltage
Power-On Time2
Output Rise Time3
Output Fall Time3
Supply Current
Reverse Battery Current
Supply Zener Clamp Voltage
Supply Zener Current4
Magnetic Characteristics5
VCC
Operating, TJ < 165°C
3.8
IOUTOFF VOUT = 24 V, B < BRP
VOUT(SAT) IOUT = 20 mA, B > BOP
tPO
Slew rate (dVCC/dt) < 2.5 V/μs, B > BOP(max) + 5 G
or B < BRP(min) – 5 G
tr
VCC = 12 V, RLOAD = 820 Ω, CS = 12 pF
tf
VCC = 12 V, RLOAD = 820 Ω, CS = 12 pF
ICCON
B > BOP
ICCOFF
B < BRP
IRCC
VRCC = –30 V
VZ
ICC = 30 mA; TA = 25°C
32
IZ
VZ = 32 V; TA = 25°C
24
V
10
μA
215 400 mV
4
μs
2
μs
2
μs
3.8 7.5 mA
3.5 7.5 mA
–10 mA
V
30 mA
A1201
–40 15
50
G
Operate Point
BOP
A1202 South pole adjacent to branded face
26
75
G
A1203 of device
26
95
G
A1204
–100 42 150
G
A1201
–50 –15 40
G
Release Point
BRP
A1202 North pole adjacent to branded face
–75 –26
G
A1203 of device
–95 –26
G
A1204
–150 –40 100
G
A1201
5
30
55
G
Hysteresis
BHYS
A1202
A1203
BOP – BRP
30
52
G
30
52
G
A1204
50
82 115
G
1 Maximum voltage must be adjusted for power dissipation and junction temperature, see Power Derating section.
2 For VCC slew rates greater than 250 V/μs, and TA = 150°C, the Power-On Time can reach its maximum value.
3 CS =oscilloscope probe capacitance.
4 Maximum current limit is equal to the maximum ICC(max) + 22 mA.
5 Magnetic flux density, B, is indicated as a negative value for north-polarity magnetic fields, and as a positive value for south-polarity magnetic fields.
This so-called algebraic convention supports arithmetic comparison of north and south polarity values, where the relative strength of the field is indicated
by the absolute value of B, and the sign indicates the polarity of the field (for example, a –100 G field and a 100 G field have equivalent strength, but
opposite polarity).
DEVICE QUALIFICATION PROGRAM
Contact Allegro for information.
EMC (Electromagnetic Compatibility) REQUIREMENTS
Contact Allegro for information.
Allegro MicroSystems, Inc.
3
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com

Share Link: 