A1210, A1211, A1212, A1213, and A1214
Continuous-Time Latch Family
OPERATING CHARACTERISTICS over full operating voltage and ambient temperature ranges, unless otherwise noted
Characteristic
Symbol
Test Conditions
Min. Typ. Max. Units
Electrical Characteristics
Supply Voltage1
Output Leakage Current
Output On Voltage
Power-On Time2
Output Rise Time3
Output Fall Time3
Supply Current
Reverse Battery Current
Supply Zener Clamp Voltage
Supply Zener Current4
Magnetic Characteristics5
VCC
IOUTOFF
VOUT(SAT)
tPO
tr
tf
ICCON
ICCOFF
IRCC
VZ
IZ
Operating, TJ < 165°C
VOUT = 24 V, B < BRP
IOUT = 20 mA, B > BOP
Slew rate (dVCC/dt) < 2.5 V/µs, B > BOP + 5 G or
B < BRP – 5 G
VCC = 12 V, RLOAD = 820 , CS = 12 pF
VCC = 12 V, RLOAD = 820 , CS = 12 pF
B > BOP
B < BRP
VRCC = –30 V
ICC = 10.5 mA; TA = 25°C
VZ = 32 V; TA = 25°C
3.8
24
V
10
µA
215 400 mV
4
µs
400 ns
400 ns
4.1 7.5 mA
3.8 7.5 mA
–10 mA
32
V
– 10.5 mA
A1210
25
78 150
G
Operate Point
A1211
15
87 180
G
BOP
A1212
South pole adjacent to branded face
of device
50 107 175
G
A1213
80
200
G
A1214
140
300
G
A1210
–150 –78 –25
G
Release Point
A1211
–180 –95 –15
G
BRP
A1212
North pole adjacent to branded face
of device
–175 –117 –50
G
A1213
–200 –
–80
G
A1214
–300 – –140 G
A1210
50 155
G
A1211
80 180
G
Hysteresis
BHYS
A1212
A1213
BOP – BRP
100 225 350
G
160
400
G
A1214
280
600
G
1 Maximum voltage must be adjusted for power dissipation and junction temperature, see Power Derating section.
2 For VCC slew rates greater than 250 V/µs, and TA = 150°C, the Power-On Time can reach its maximum value.
3 CS =oscilloscope probe capacitance.
4 Maximum current limit is equal to the maximum ICC(max) + 3 mA.
5 Magnetic flux density, B, is indicated as a negative value for north-polarity magnetic fields, and as a positive value for south-polarity magnetic fields.
This so-called algebraic convention supports arithmetic comparison of north and south polarity values, where the relative strength of the field is indicated
by the absolute value of B, and the sign indicates the polarity of the field (for example, a –100 G field and a 100 G field have equivalent strength, but
opposite polarity).
DEVICE QUALIFICATION PROGRAM
Contact Allegro for information.
EMC (Electromagnetic Compatibility) REQUIREMENTS
Contact Allegro for information.
A1210-DS
Allegro MicroSystems, Inc.
3
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com