A29DL32x Series
Autoselect Mode
The autoselect mode provides manufacturer and device
identification, and sector protection verification, through
identifier codes output on I/O7 - I/O0. This mode is primarily
intended for programming equipment to automatically match
a device to be programmed with its corresponding
programming algorithm. However, the autoselect codes can
also be accessed in-system through the command register.
When using programming equipment, the autoselect mode
requires VID (8.5V to 12.5 V) on address pin A9. Address
pins A6, A1, and A0 must be as shown in Table 5. In
addition, when verifying sector protection, the sector address
must appear on the appropriate highest order address bits.
(see Table 3-4). Table 5 shows the remaining address bits
that are don't care. When all necessary bits have been set as
required, the programming equipment may then read the
corresponding identifier code on I/O7 - I/O0.
To access the autoselect codes in-system, the host system
can issue the autoselect command via the command
register, as shown in Table 12. This method does not require
VID. Refer to the Autoselect Command Sequence section for
more information.
Table 5. A29DL32x Autoselect Codes (High Voltage Method)
I/O8 to I/O15
A20 A11
A8
A5
I/O7
Description
CE OE
WE to
A12
to
A10
A9
to
A7
A6
to A3 A2
A4
A1 A0
BYTE BYTE
to
I/O0
= VIH = VIL
Manufacturer ID:
AMIC
LL
Device ID: A29DL322 L L
H BA X VID X L X L L L L
X
H BA X VID X L X X X L H 22h
X
37h
X 55h (T), 56h (U)
Device ID: A29DL323 L L
H BA X VID X L X X X L H 22h
X 50h (T), 53h (U)
Device ID: A29DL324 L L
H BA X VID X L X X X L H 22h
X 5Ch (T), 5Fh (U)
Continuation ID
LL
H
X
X VID X L X X X H H
X
X
7Fh
Read Sector Status
LL
H SA X VID X L X L L H L
X
X
01h (protected),
00h (unprotected)
L=Logic Low= VIL, H=Logic High=VIH, SA=Sector Address, X=Don’t Care, BA=Bank Address
Note: The autoselect codes may also be accessed in-system via command sequences.