datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

A29DL324TV-80 Ver la hoja de datos (PDF) - AMIC Technology

Número de pieza
componentes Descripción
Lista de partido
A29DL324TV-80 Datasheet PDF : 50 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
A29DL32x Series
START
PLSCNT=1
RESET=VID
Wait 1 us
Protect all sectors:
The indicated portion of
the sector protect
algorithm must be
performed for all
unprotected sectors prior
to issuing the first sector
unprotect address
START
PLSCNT=1
RESET=VID
Wait 1 us
Temporary Sector No
Unprotect Mode
First Write
Cycle=60h?
Yes
Set up sector
address
Sector Protect:
Write 60h to sector
address with A6=0,
A1=1, A0=0
No
First Write No Temporary Sector
Cycle=60h?
Unprotect Mode
Yes
All sectors
protected?
Yes
Set up first sector
address
Increment
PLSCNT
Wait 150 us
Verify Sector
Protect: Write 40h
to sector address
with A6=0, A1=1,
A0=0
Reset
PLSCNT=1
No
PLSCNT
=25?
Read from
sector address
with A6=0,
A1=1, A0=0
No
Data=01h?**
Yes
Device failed
Yes
Protect another
Yes
sector?
No
Remove VID
from RESET
Sector Unprotect:
Write 60h to sector
address with A6=1,
A1=1, A0=0
Increment
PLSCNT
Wait 15 ms
Verify Sector
Unprotect : Write
40h to sector
address with A6=1,
A1=1, A0=0
No
PLSCNT=
1000?
Yes
Device failed
Read from sector
address with A6=1,
A1=1, A0=0
No
Data=00h?**
Set up
next sector
address
Yes
Last sector
No
verified?
Sector Protect
Algorithm
Write reset
command
Sector Protect
complete
Sector Unprotect
Algorithm
Yes
Remove VID
from RESET
Write reset
Command
Note: The term “sector” in the figure applies to both sectors and sector blocks
* No other command is allowed during this process
** Read access time is 200ns-300ns
Sector Unprotect
complete
Figure 2-1. High Voltage Sector/Sector Block Protection and Unprotection Algorithms
PRELIMINARY (May, 2005, Version 0.0)
16
AMIC Technology, Corp.

Share Link: 