datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

A29DL322UG-120 Ver la hoja de datos (PDF) - AMIC Technology

Número de pieza
componentes Descripción
Lista de partido
A29DL322UG-120 Datasheet PDF : 50 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
A29DL32x Series
START
PLSCNT=1
555/AA + 2AA/55 +
555/77
Wait 1 us
Protect all sectors:
The indicated portion of
the sector protect
algorithm must be
performed for all
unprotected sectors prior
to issuing the first sector
unprotect address
START
PLSCNT=1
555/AA + 2AA/55 +
555/77
Wait 1 us
Temporary Sector No
Unprotect Mode
First Write
Cycle=60h?
Yes
Set up sector
address
Sector Protect:
Write 60h to sector
address with A6=0,
A1=1, A0=0
No
First Write No Temporary Sector
Cycle=60h?
Unprotect Mode
Yes
All sectors
protected?
Yes
Set up first sector
address
Increment
PLSCNT
Wait 150 us
Verify Sector
Protect: Write 40h
to sector address
with A6=0, A1=1,
A0=0
Reset
PLSCNT=1
No
PLSCNT
=25?
Read from
sector address
with A6=0,
A1=1, A0=0
No
Data=01h?**
Yes
Device failed
Yes
Protect another
Yes
sector?
No
Write reset
command
Sector Unprotect:
Write 60h to sector
address with A6=1,
A1=1, A0=0
Increment
PLSCNT
Wait 15 ms
Verify Sector
Unprotect : Write
40h to sector
address with A6=1,
A1=1, A0=0
No
PLSCNT=
1000?
Yes
Device failed
Read from sector
address with A6=1,
A1=1, A0=0
No
Data=00h?**
Set up
next sector
address
Yes
Last sector
No
verified?
Sector Protect
Algorithm
Sector Protect
complete
Sector Unprotect
Algorithm
Yes
Write reset
Command
Sector Unprotect
complete
Note: The term “sector” in the figure applies to both sectors and sector blocks
* No other command is allowed during this process
** Read access time is 200ns-300ns
Figure 2-2. Software Sector/Sector Block Protection and Unprotection Algorithms
PRELIMINARY (May, 2005, Version 0.0)
17
AMIC Technology, Corp.

Share Link: 