A43L8316
Function Truth Table (Table 1, Continued)
Current
State
CS RAS CAS WE BA
HX XXX
L H HHX
Write with L
H
H
L
X
Auto
L H L H BA
Precharge L
H
L
L BA
L L H X BA
L
L
L
X
X
HX XXX
L H HHX
LHHLX
Precharge L
H
L
X BA
L L H H BA
L L H L BA
L
L
L
X
X
HX XXX
L H HHX
Row
LHHLX
Activating L H L X BA
L L H H BA
L L H L BA
L
L
L
X
X
HX XXX
LHHXX
Refreshing L
H
L
X
X
L L HXX
L
L
L
X
X
Address
Action
X
X
X
CA,A8/AP
CA,A8/AP
RA, PA
X
X
X
X
CA,A8/AP
RA
PA
X
X
X
X
CA,A8/AP
RA
PA
X
X
X
X
X
X
NOP(Continue Burst to EndPrecharge)
NOP(Continue Burst to EndPrecharge)
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
NOPIdle after tRP
NOPIdle after tRP
ILLEGAL
ILLEGAL
ILLEGAL
NOPIdle after tRP
ILLEGAL
NOPRow Active after tRCD
NOPRow Active after tRCD
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
NOPIdle after tRC
NOPIdle after tRC
ILLEGAL
ILLEGAL
ILLEGAL
Note
2
2
2
2
2
2
4
2
2
2
2
Abbreviations
RA = Row Address
NOP = No Operation Command
BA = Bank Address
CA = Column Address
AP = Auto Precharge
PA = Precharge All
Note: 1. All entries assume that CKE was active (High) during the preceding clock cycle and the current clock cycle.
2. Illegal to bank in specified state : Function may be legal in the bank indicated by BA, depending on the state of
that bank.
3. Must satisfy bus contention, bus turn around, and/or write recovery requirements.
4. NOP to bank precharging or in idle state. May precharge bank indicated by BA (and PA).
5. Illegal if any banks is not idle.
Preliminary (April, 2000, Version 1.0)
41