Figure 23: Automatic Byte Program Algorithm
Start
Write Command
Address: 5555H
Data: AAH
A49FL004
Write Command
Address: 2AAAH
Data: 55H
Write Command
Address: 5555H
Data: A0H
Write Command
Address: PA
Data: PD
NO
I/O7 = Data ?
Or
I/O6 Stop Toggle?
YES
Byte Program
Completed
PA: Byte Program Address
PD: Byte Program Data
PRELIMINARY (September, 2005, Version 0.0)
29
AMIC Technology, Corp.