TYPICAL APPLICATION CONT’D
VFB Sampling Waveforms
ACT361 senses the output voltage information
through the VFB waveforms. Proper VFB waveforms
are required for IC to operate in a stable status. To
avoid mis-sampling, 1.38µs blanking time is added
to blank the ringing period due to the leakage
inductance and the circuit parasitic capacitance.
Figure 2 is the recommended VFB waveform to
guarantee the correct sampling point so that the
output information can be sent back into the IC to
do the appropriate control.
Figure 2:
1.38µs
ACT361
Rev 8, 14-Nov-12
Innovative PowerTM
-8-
www.active-semi.com