datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

ACT8862Q4I134-T Ver la hoja de datos (PDF) - Active-Semi, Inc

Número de pieza
componentes Descripción
Lista de partido
ACT8862Q4I134-T
ACTIVE-SEMI
Active-Semi, Inc ACTIVE-SEMI
ACT8862Q4I134-T Datasheet PDF : 31 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ACT8862
Rev 1, 04-Sep-13
REGISTER AND BIT DESCRIPTIONS CONT’D
OUTPUT
REG2
REG2
REG2
REG2
REG2
REG2
REG2
REG3
REG3
REG3
REG3
REG3
REG3
REG3
REG3
REG3
REG3
REG4
REG4
REG4
REG4
REG4
REG4
REG4
ADDRESS
0x31
0x32
0x32
0x32
0x32
0x32
0x32
0x40
0x40
0x41
0x41
0x42
0x42
0x42
0x42
0x42
0x42
0x50
0x50
0x51
0x51
0x51
0x51
0x51
BIT
[5:0]
[7]
[6]
[5]
[4:2]
[1]
[0]
[7:6]
[5:0]
[7:6]
[5:0]
[7]
[6]
[5]
[4:2]
[1]
[0]
[7:6]
[5:0]
[7]
[6]
[5]
[4:2]
[1]
NAME
VSET2
ON
PHASE
MODE
DELAY
nFLTMSK
OK
-
VSET1
-
VSET2
ON
PWRSTAT
MODE
DELAY
nFLTMSK
OK
-
VSET
ON
DIS
LOWIQ
DELAY
nFLTMSK
ACCESS
DESCRIPTION
Secondary Output Voltage Selection. Valid when VSEL is
R/W driven high. See the Output Voltage Programming section for
more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
Regulator Phase Control. Set bit to 1 for regulator to operate
R/W 180° out of phase with the oscillator, clear bit to 0 for regulator
to operate in phase with the oscillator.
Regulator Mode Select. Set bit to 1 for fixed-frequency PWM
R/W under all load conditions, clear bit to 0 to transit to power-
savings mode under light-load conditions.
R/W
Regulator Turn-On Delay Control. See the REG1, REG2,
REG3 Turn-on Delay section for more information.
R/W
Regulator Fault Mask Control. Set bit to 1 enable to fault-
interrupts, clear bit to 0 to disable fault-interrupts.
R/W
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
Primary Output Voltage Selection. Valid when VSEL is driven
R/W low. See the Output Voltage Programming section for more
information.
R Reserved.
Secondary Output Voltage Selection. Valid when VSEL is
R/W driven high. See the Output Voltage Programming section for
more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R/W
Configures regulator behavior with respect to the nPBIN input.
Set bit to 0 to enable regulator when nPBIN is asserted.
Regulator Mode Select. Set bit to 1 for fixed-frequency PWM
R/W under all load conditions, clear bit to 0 to transition to power-
savings mode under light-load conditions.
R/W
Regulator Turn-On Delay Control. See the REG1, REG2,
REG3 Turn-on Delay section for more information.
R/W
Regulator Fault Mask Control. Set bit to 1 enable to fault-
interrupts, clear bit to 0 to disable fault-interrupts.
R/W
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage
Programming section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
Output Discharge Control. When activated, discharges LDO
R/W
output to GA through 1.5kwhen in shutdown. Set bit to 1 to
enable output voltage discharge in shutdown, clear bit to 0 to
disable this function.
R/W
LDO Low-IQ Mode Control. Set bit to 1 for low-power
operating mode, clear bit to 0 for normal mode.
R/W
Regulator Turn-On Delay Control. See the REG4, REG5,
REG6, REG7 Turn-on Delay section for more information.
R/W
Regulator Fault Mask Control. Set bit to 1 enable to fault-
interrupts, clear bit to 0 to disable fault-interrupts.
Innovative PowerTM
- 11 -
Active-Semi ProprietaryFor Authorized Recipients and Customers
ActivePMUTM is a trademark of Active-Semi.
I2CTM is a trademark of NXP.
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.

Share Link: 