AD8352
Parameter
Conditions
Min
Typ
Max
Unit
190 MHz
Second/Third Harmonic Distortion
RL = 1 kΩ, VOUT = 2 V p-p
−82/−85
dBc
RL = 200 Ω, VOUT = 2 V p-p
−81/−87
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 180.5 MHz, f2 = 190.5 MHz
+39
dBm
Third-Order IMD
RL = 1 kΩ, f1 = 180.5 MHz, f2 = 190.5 MHz,
VOUT = 2 V p-p composite
−83
dBc
RL = 200 Ω, f1 = 180.5 MHz, f2 = 190.5 MHz,
−81
dBc
VOUT = 2 V p-p composite
Noise Spectral Density (RTI)
+2.7
nV/√Hz
1 dB Compression Point (RTO)
+15.4
dBm
240 MHz
Second/Third Harmonic Distortion
RL = 1 kΩ, VOUT = 2 V p-p
−82/−76
dBc
RL = 200 Ω, VOUT = 2 V p-p
−80/−73
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 239.5 MHz, f2 = 240.5 MHz
+36
dBm
Third-Order IMD
RL = 1 kΩ, f1 = 239.5 MHz, f2 = 240.5 MHz,
VOUT = 2 V p-p composite
−85
dBc
RL = 200 Ω, f1 = 239.5 MHz, f2 = 240.5 MHz,
−77
dBc
VOUT = 2 V p-p composite
Noise Spectral Density (RTI)
+2.7
nV/√Hz
1 dB Compression Point (RTO)
+15.3
dBm
380 MHz
Second/Third Harmonic Distortion2 RL = 1 kΩ, VOUT = 2 V p-p
−72/−68
dBc
RL = 200 Ω, VOUT = 2 V p-p
−74/−69
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 379.5 MHz, f2 = 380.5 MHz
+33
dBm
Third-Order IMD
RL = 1 kΩ, f1 = 379.5 MHz, f2 = 380.5 MHz,
VOUT = 2 V p-p composite
−74
dBc
RL = 200 Ω, f1 = 379.5 MHz, f2 = 380.5 MHz,
−70
dBc
VOUT = 2 V p-p composite
Noise Spectral Density (RTI)
+2.7
nV/√Hz
1 dB Compression Point (RTO)
+14.6
dBm
500 MHz
Second/Third Harmonic Distortion
RL = 200 Ω, VOUT = 2 V p-p
−71/−64
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 499.5 MHz, f2 = 500.5 MHz
+28
dBm
Third-Order IMD
RL = 200 Ω, f1 = 499.5 MHz, f2 = 500.5 MHz,
−61
dBc
VOUT = 2 V p-p composite
Noise Spectral Density (RTI)
+2.7
nV/√Hz
1 dB Compression Point (RTO)
+13.9
dBm
1 When using the evaluation board at frequencies below 50 MHz, replace the Output Balun T1 with a transformer such as Mini-Circuits® ADT1-1WT to obtain the low
frequency balance required for differential HD2 cancellation.
2 CD and RD can be optimized for broadband operation below 180 MHz. For operation above 300 MHz, CD and RD components are not required.
Rev. A | Page 5 of 20