datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

CDB4344 Ver la hoja de datos (PDF) - Cirrus Logic

Número de pieza
componentes Descripción
Lista de partido
CDB4344
Cirrus-Logic
Cirrus Logic Cirrus-Logic
CDB4344 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
CDB4344
JUMPER /
SWITCH
J4
PURPOSE
Selects source of voltage
for the CS4344 VA supply
J7
Provides contact points to
measure current
S1
Resets CS8416
S2
Sets clock source
Sets MCLK ratio of CS8416
POSITION
VA
+3.3V
*+5V
-
left
right
FUNCTION SELECTED
Voltage source is the +3.3V to +5V binding post
Voltage source is a +3.3V regulator
Voltage source is +5V binding post
Measure voltage across these nodes and divide
result by 10 to get current in Amps
The CS8416 must be reset if switch S2 is
changed
Sets clock source for CS4344 (open=J9, *closed
= CS8416)
Selects 128x (open) or 256x (*closed)
MCLK/LRCK ratio output for CS8416
*Default Factory Settings.
Table 2. CDB4344 Jumper Settings
7. ERRATA
CDB4344 Revision B.0
Switch S2 is oriented incorrectly on some boards (if open is away from binding posts) and thus
the 0 and 1 labels above and below are incorrect. Using closed for 0 and open for 1, the table
next to the switch will be correct.
DS613DB2
5

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]