CF5029A
FUNCTIONAL DESCRIPTION
Standby Function
When INHN goes LOW, the device is in standby mode. The Q output becomes high impedance and the oscilla-
tor circuit stops.
INHN
HIGH (or open)
LOW
Q
f O /512
High impedance
Oscillator
Normal operation
Stopped
Power-saving Pull-up Resistor
The INHN pin pull-up resistance changes in response to the input level (HIGH or LOW). When INHN is tied
LOW, the pull-up resistance becomes large, reducing the current consumed by the resistance. When INHN is
open circuit, the pull-up resistance becomes small, decreasing the susceptibility to the effects of external noise.
SEIKO NPC CORPORATION —5