CS5529
FAQs
9) Is calibration required to use the converter?
A: When the CS5525/26 is reset, the registers are set to known values. If the
signal to be measured by the converter is within the nominal range, the
converter can perform conversions without the need for calibrations.
Errors in the system remain present when calibration is not performed,
however, this may be acceptable if the errors are insignificant to the mea-
surement or if the errors are removed by some other means, such as soft-
ware and registers in the microcontroller.
10) How often do I need to recalibrate?
A: To answer this question one must ask: 1) What accuracy is required from
the A/D converter? 2) What effects will temperature changes have upon
the entire circuit, including components outside the A/D? To obtain opti-
mum calibration accuracy, a calibration should be performed approxi-
mately one minute after power is applied to allow the chip to reach
thermal equilibrium.
A higher accuracy measurement requirement will generally require cali-
brations more often, because, after the initial calibration has been per-
formed, the converter is subject to some drift if the operating temperature
changes. Typical offset drift and gain drift are given in the data sheet
tables. The observed drift in the application circuit may be considerably
greater due to parasitic thermocouple effects and gain drift caused by the
limited tempco tracking of the external resistors. Once an estimate of
drift is determined for the entire application circuit (drift will usually be
dominated by error sources external to the converter), an assessment of
how it affects measurement accuracy as temperature changes can be
made. Once the amount of drift is known, you can determine if a new cal-
ibration is required. A good rule of thumb is to recalibrate the converter
(or system) with every ten degrees of ambient temperature change.