100-264Vac POWER SUPPLY BOARD FOR DMS-30 METERS
Applications
4. DC Current Measurements (Use +/-200mV Range DMS-30-0 Meters):
When using R2 location for a dc current-shunt, please note that the pc-
board copper traces which short out R1 can only carry currents up to
0.2A (200mA). However, dc currents up to 2A can be accommodated if a
20AWG jumper wire is soldered in location R1. Be sure R2 has a
sufficient power rating to safely carry the full load current. Refer to DMS
Application Note 6 for more information on dc ammeters.
1. Install R2: R2 = FSR / (IMAX . x 10000) where FSR is the desired meter
reading (0 up to 1999, disregarding any decimal points), and IMAX is
current in Amperes.
2. Configure the DMS-EB for span adjust using the procedure previously
outlined for the DMS-30-0 (+/-200mV range).
3. Apply the input signal (current) to TB1 (+) HI and (–) LO.
4. Adjust R4 for desired full scale readings.
5. Enable the appropriate decimal point using SG1, SG2, or SG3.
Example
Using a DMS-30-0 meter, a 0.100 Ampere input must read “100.0” mA on
the display.
R2 = 1000 / (0.1 x 10000)
R2 = 1 Ohm
Enable DP3 via SG3 for a display reading of “100.0”.
12
SG10
R5
SG14
SG7
SG8
SG4 DP4
SG13
SG6 TB1
R4
SG12
SG11
R3
SG9
1
2
HI(+) LO(–)
Figure 3. R4 and R5 Installation
R1
12
R2
SG14
SG7
SG8
SG4 DP4
SG13
SG6 TB1
SG11
R3
SG12
SG9
1
2
HI(+) LO(–)
Figure 4. R1 and R2 Installation
®
®
ISO 9001
REGISTERED
www.datel.com
DS-0341B 09/02
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
Internet: www.datel.com Email: sales@datel.com
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444
DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01
DATEL GmbH München, Germany Tel: 89-544334-0
DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions
contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL,
Inc. trademark.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]