ETC5064 - ETC5064-X - ETC5067 - ETC5067-X
TRANSMISSION CHARACTERISTICS
(all devices) TA = 0°C to 70°C (ETC5064-X/67-X: TA = –40°C to 85°), VCC = 5V ± 5%, VBB = – 5V ± 5%,
GNDA = 0V, f = 1.02kHz, VIN = 0dBm0 transmit input amplifier connected for unity–gain non–inverting. (unless
otherwise specified).
AMPLITUDE RESPONSE
Symbol
Parameter
Min. Typ. Max. Unit
Absolute Levels - Nominal 0 dBm0 is 4 dBm (600).
0 dBm0
1.2276
Vrms
tMAX
Max Overload Level
3.14 dBm0
3.17 dBm0
ETC5067
ETC5064
2.492
2.501
VPK
GXA
Transmit Gain, Absolute (TA = 25°C, VCC = 5V, VBB = -5V)
Input at GSX = 0dBm0 at 1020Hz
-0.15
0.15
dB
GXR Transmit Gain, Relative to GXA
f = 16Hz
-
-40
te Product(s) GXAT
sole GXAV
Ob GXRL
ct(s) - GRA
rodu GRR
Obsolete P GRAT
f = 50Hz
f = 60Hz
f = 180Hz
f = 200Hz
f = 300Hz -3000Hz
f = 3200Hz (ETC5064-X/67-X)
f = 3300Hz
f = 3400Hz
f = 4000Hz
f = 4600Hz and up, measure response from oHz to 4000Hz
Absolute Transmit Gain Variation with Temperature
TA = 0°C to +70°C
TA = –40°C to +85°C (ETC5064-X/67-X)
Absolute Transmit Gain Variation with Supply Voltage
(VCC = 5V ±5%, VBB = -5V ±5%)
Transmit Gain Variation with Level
Sinusolidal Test Method Reference Level = -10dBm0
VFXI+ = -40dBm0 to +3dBm0
VFXI+ = -50dBm0 to -40dBm0
VFXI+ = -55dBm0 to -50dBm0
Receive Gain, Absolute (TA = 25°C, VCC = 5V, VBB = -5V)
Input = Digital Code Sequence for 0dBm0 Signal at 1020Hz
Receive Gain, Relative to GRA
f = 0Hz to 3000Hz
f = 3200Hz (ETC5064-X/67-X)
f = 3300Hz
f = 3400Hz
f = 4000Hz
Absolute Receive Gain Variation with Temeperature
TA = 0°C to +70°C
TA = –40°C to +85°C (ETC5064-X/67-X)
-
-
-2.8
-1.8
-0.15
-0.35
-0.35
-0.7
-0.1
-0.15
-0.05
-0.2
-0.4
-1.2
-0.15
-0.15
-0.35
-0.35
-0.7
-0.1
-0.15
-30
-26
-0.2
-0.1
0.15
dB
0.20
0.05
0
-14
-32
dB
0.1
0.15
0.05
dB
0.2
dB
0.4
1.2
0.15
dB
0.15
0.20
dB
0.05
0
-14
0.1
dB
0.15
GRAV
Absolute Receive Gain Variation with Supply Voltage
(VCC = 5V ±5%, VBB = -5V ±5%)
-0.05
0.05
dB
GRRL
Receive Gain Variation with Level
Sinusoidal Test Method; Reference Input PCM code
corresponds to an ideally encoded -10dBm0 signal
PCM level = -40dBm0 to +3dBm0
PCM level = -50dBm0 to -40dBm0
PCM level = -55dBm0 to -50dBm0
-0.2
0.2
dB
-0.4
0.4
-1.2
1.2
VRO
Receive Filter Output at VFRO RL = 10K
-2.5
2.5
V