datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

RP03-1205DB Ver la hoja de datos (PDF) - RECOM Electronic GmbH

Número de pieza
componentes Descripción
Lista de partido
RP03-1205DB Datasheet PDF : 4 Pages
1 2 3 4
POWERLINE
DC/DC-Converter
RP03-S_DB
(DB/DS) Series
Specifications (typical at nominal input and 25°C unless otherwise noted)
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Operating Frequency
Approved to Safety Standards
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance
Thermal Shock
Vibration
Relative Humidity
Case Material
Base Material
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Weight
Dimensions
MTBF (see note 2)
In to out
I/O to case
Output to Output
Standard
M1 (see note 3)
Natural convection
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
DIP
SMD
DIP
SMD
DIP at SMD type
/DS type
500VDC min.
500VDC min.
500VDC min.
109 min.
300pF max.
300kHz typ.
UL 1950, EN60950
-25°C to +85°C (with derating)
-40°C to +85°C (non-derating)
+100°C
-55°C to +105°C
20°C/Watt
MIL-STD-810D
10-55Hz, 2G, 30 Min. along X, Y and Z
5% to 95% RH
Nickel-Coated copper
Non-conductive black plastic
Epoxy (UL94-V0)
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
16g
18g
31.8 x 20.3 x 10.2mm
32.0 x 20.3 x 10.9mm
3.069 x 106 Hours
Notes :
1. The RP03 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under
no-load condition will not damage these devices, however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. Should an O/O isolation be required, please order the converter with the following part number: RP03-XXXXDB/DS.
8. The “M1” version (RP03-xxxxSB-M1 / RP03-xxxxDB-M1) and the dual-isolated-output-version (RP03-xxxxDS) do not carry the UL certification.
9. See application notes for EMI-filtering.
172
April-2005
www.recom-international.com

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]