Absolute Maximum Ratings (Note 1)
Supply Voltage (VCC )
DC Input Voltage (VI)
Output Voltage (VO)
Outputs 3-stated
Outputs Active (Note 2)
DC Input Diode Current (IIK) VI < 0V
DC Output Diode Current (IOK)
VO < 0V
VO > Vcc
DC Output Source/Sink Current (IOH/IOL)
DC VCC or Ground Current per
Supply Pin (ICC or Ground)
Storage Temperature Range (TSTG)
-0.5V to +6.5V
-0.5V to +6.5V
-0.5V to +6.5V
-0.5 to VCC+0.5V
-50mA
-50mA
+50mA
±50mA
±100mA
-65°C to +150°C
Recommended Operating Conditions
(Note 3)
Power Supply
3.0V to 5.5V
Input Voltage
-0.3V to 5.5V
Output Voltage (VO)
Output Current IOL
Free Air Operating Temperature(TA)
0V to VCC
3mA
-0°C to +70°C
Minimum Input Edge Rate (dt/dv)
VIN = 0.8V to 2.0V, VCC = 3.0V
10ns/V
Note 1: The “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The
parametric values defined in the “Electrical Characteristics” table are not guaranteed at the Absolute Maximum Ratings. The “Recommended Operating Conditions” table will
define the conditions for actual device operation.
Note 2: IO Absolute Maximum Rating must be observed.
Note 3: Floating or unused pins (inputs or I/O’s) must be held HIGH or LOW.
DC Electrical Characteristics (4.5V < VCC ≤ 5.5V unless stated otherwise)
Symbol
Parameter
Conditions
Min
VIH
High Level Input Voltage
VIL
Low Level Input Voltage
VOL
Low Level Output Voltage
IIR
Input Leakage Current
ICC
Quiescent Supply Current
IOL = 100µA
IOL = 3mA
VI=VIL, VCC = 5.5V
VI = VCC or GND
VCC ≤ (VI, VO) ≤ 3.6V
VCC x 0.7
-10
300
Max
VCC x 0.3
0.2
0.4
+10
975
Units
V
V
V
µA
µA
DC Electrical Characteristics Extended (3.0V ≤ VCC ≤ 5.5V unless stated otherwise)
Symbol
Parameter
Conditions
Min
Max
VIH
High Level Input Voltage
VIL
Low Level Input Voltage
VOL
Low Level Output Voltage
VOH
Output High Voltage
IOL = 100µA
IOL = 3mA
Fixed output mode, ('S' grade
samples, or FM3560 with
LEVEL input = logical ‘0’) 1
TTL load, 50pF capacitance
VCC x 0.7
2.3
VCC x 0.3
0.2
0.4
2.5
IIR
Input Leakage Current
ICC
Quiescent Supply Current
VI=VIL, VCC = 5.5V
VCC ≤ (VI, VO) ≤ 3.6V
-10
+10
300
975
Units
V
V
V
V
µA
µA
FM3565 Rev. A.1
5
www.fairchildsemi.com