PATENTED
Command Mode (Command ID Code: 1 0 0)
CS
HT1670
WR
RD
DB3
X C7 C3 X X
DB2
1 C6 C2 X X
DB1
0 C5 C1 X X
DB0
0 C4 C0 X X
X C7 C3 X X C7 C3 X X C7 C3 X X C7 C3 X X C7 C3
1 C6 C2 X X C6 C2 X X C6 C2 X X C6 C2 X X C6 C2
0 C5 C1 X X C5 C1 X X C5 C1 X X C5 C1 X X C5 C1
0 C4 C0 X X C4 C0 X X C4 C0 X X C4 C0 X X C4 C0
( S in g le c o m m a n d )
Note: ²X² stands for don¢t care
Application Circuits
Host Controller With an HT1670 Display System
( S u c c e s s iv e c o m m a n d )
M CU
C lo c k O u t
E x te r n a l C lo c k 1 ( 3 2 k H z )
E x te r n a l C lo c k 2 ( 3 2 k H z )
O n - c h ip O S C
C ry s ta l
32768H z
CS
*
RD
WR
D B 0~D B 3
*R
IR Q
O SCI
H T1670
M ax.
7V
V LC D
BZ
BZ
*V R
P ie z o
O S C O C O M 0 ~ C O M 31 S E G 0~S E G 127
* 1 /6 B ia s o r 1 /5 B ia s ,
1 /3 2 D u ty o r 1 /1 6 D u ty
* LC D P anel
*Note: The connection of IRQ and RD pin can be selected depending on the MCU.
Adjust VR to fit LCD display
Adjust R (external pull-high resistance) to fit user¢s time base clock.
It is recommended that the internal equivalent capacitance between SEG and COM of LCD panel should be
lower than 10pF. (LCR meter test condition: frequency in 1kHz)