datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

IK3051 Ver la hoja de datos (PDF) - IK Semicon Co., Ltd

Número de pieza
componentes Descripción
Lista de partido
IK3051 Datasheet PDF : 5 Pages
1 2 3 4 5
IK3051
Absolute Maximum Ratings
Symbol
Vcc
Vi
Top
Tj
Parameter
DC Supply Voltage
Input Voltage
Operating Free Air Temperature Range
Maximum Junction Temperature
Value
Unit
14
V
-0.3 to Vcc
V
0 to 85
oC
150
oC
Operation Conditions
Symbol
Vcc
Parameter
DC Supply Conditions
Value
Unit
2.5 to 12
V
Electrical Characteristics
Tamb = 25°C and Vcc = +5V (unless otherwise specified)
Symbol
Parameter
Total Current Consumption
Icc
Total Supply Current – not taking the
output sinking current into account
Voltage Control Loop
Gmv
Transconduction Gain (Vctrl). Sink
Current Only 1)
Vref Voltage Control Loop Reference 2)
Iibv Input Bias Current (Vctrl)
Current Control Loop
Gmi
Transconduction Gain (Ictrl). Sink
Current Only 3)
Vsense Current Control Loop Reference 4)
Iibi Current out of pin Ictrl at -200mV
Output Stage
Vol
Low output voltage at 10 mA sinking
current
Ios
Output Short Circuit Current. Output
to Vcc. Sink Current Only
Test Condition
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Iout = 2.5 mA Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Min Typ Max
1.1 2
1.2
1
1.198
1.186
3.5
2.5
1.21
50
100
1.222
1.234
1.5 7
196
192
200
204
208
25
50
200
27
35
50
Unit
mA
mA/mV
V
nA
mA/mV
mV
μA
mV
mA
1. If the voltage on Vctrl (the negative input of the amplifier) is higher than the positive amplifier input (Vref=1.210V), and
it is increased by 1mV, the sinking current at the output OUT will be increased by 3.5mA.
2. The internal Voltage Reference is set at 1.210V (bandgap reference). The voltage control loop precision takes into
account the cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-
conductance operational amplifier. The internal Voltage Reference is fixed by bandgap, and trimmed to 0.5% accuracy at
room temperature.
3. When the positive input at Ictrl is lower than -200mV, and the voltage is decreased by 1mV, the sinking current at the
output OUT will be increased by 7mA.
4. The internal current sense threshold is set to -200mV. The current control loop precision takes into account the
cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-conduction
operational amplifier.
Rev. 00

Share Link: 