Dimensions LF 1005-S (in mm. 1 mm = 0.0394 inch)
Bottom view
Front view
Back view
Top view
Secondary terminals
Pin + : supply voltage + 15 .. 24 V
Pin M : measure
Pin - : supply voltage - 15 .. 24 V
Connection
Mechanical characteristics
• General tolerance
• Transducer fastening
Vertical position
Fastening torque, maxi
or
Fastening torque, maxi
or
Fastening torque, maxi
• Transducer fastening
Horizontal position
Fastening torque, maxi
or
Fastening torque, maxi
• Primary through-hole
• Connection of secondary
± 0.5 mm
2 holes ∅ 5.3 mm
2 M5 steel screws
4 Nm or 2.52 Lb. - Ft.
4 holes ∅ 4.2 mm
4 M4 steel screws
3.2 Nm or 2.02 Lb. - Ft.
4 holes ∅ 2.25 mm depth10 mm
4 x PT KA30screws long 10 mm
0.9 Nm or 0.57 Lb. - Ft.
4 holes ∅ 5.3 mm
4 M5 steel screws
4 Nm or 2.52 Lb. - Ft.
4 holes ∅ 2.25 mm depth16 mm
4 x PT KA30screws long 16 mm
1 Nm or 0.63 Lb. - Ft.
40.5 x 40.5 mm
Molex 5045-03/AG
Remarks
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.