Dimensions LTC 600-SFC (in mm. 1 mm = 0.0394 inch)
Front view
Customer bar
Left view
Secondary terminals
Terminal + : supply voltage + 15 .. 24 V
Terminal M : measure
Terminal - : supply voltage - 15 .. 24 V
Terminal E : shield
Connection
or
Top view
Mechanical characteristics
• General tolerance
• Fixing the transducer
Fastening torque max
• Primary through-hole
• Connection of secondary
Fastening torque max
± 1 mm
4 slots ∅ 6.5 mm
4 screws M6
5 Nm
∅ 42 mm
M5 threaded studs
2.2 Nm or 1.62 Lb.-Ft.
Faston 6.3 x 0.8 mm
Remarks
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.