Integrated
Circuit
Systems, Inc.
M2006-12A
VCSO BASED FEC CLOCK PLL WITH HITLESS
ABSOLUTE MAXIMUM RATINGS1
Symbol Parameter
Rating
Unit
VI
Inputs
-0.5 to VCC +0.5
V
VO Outputs
-0.5 to VCC +0.5
V
VCC Power Supply Voltage
4.6
V
TS Storage Temperature
-45 to +100
oC
Table 9: Absolute Maximum Ratings
Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the
device. These ratings are stress specifications only. Functional operation of product at these conditions
or any conditions beyond those listed in Recommended Conditions of Operation, DC Characteristics, or
AC Characteristics is not implied. Exposure to absolute maximum rating conditions for extended periods
may affect product reliability.
RECOMMENDED CONDITIONS OF OPERATION
Symbol Parameter
Min Typ Max Unit
VCC Positive Supply Voltage
3.135 3.3 3.465 V
TA Ambient Operating Temperature
Commercial
0
+70
oC
Industrial
-40
+85
oC
Table 10: Recommended Conditions of Operation
M2006-12A Datasheet Rev 1.0
6 of 10
Revised 28Jul2004
Integrated Circuit Systems, Inc. ● Networking & Communications ● www.icst.com ● tel (508) 852-5400